SITRANS TF280 WirelessHART temperature transmitter |
Input | |
Sensor | |
| Pt100 as per IEC 751/EN 607511) |
| Two, three or four-wire system |
| -200 ... +850 °C (-328 ... +1560 °F) |
Cable length SITRANS TF280 and Pt100 sensor element | ? 3 m |
Measuring accuracy2) | |
Accuracy | < 0.4 % of the measured value |
Long-term drift | < 0.035 % of the measuring range in first year |
Temperature drift | Max. ±0.01 °C/10 K |
Rated conditions | |
Ambient temperature | -40 ... +80 °C (-40 ... +176 °F) |
Storage temperature | -40 ... +85 ° C (-40 ... +185 °F) |
Relative humidity | < 95% |
Climatic class | 4K4H in accordance with EN 60721-3-4 (stationary use at locations not protected against weather) |
Degree of protection | IP65/NEMA 4 |
Max. permissible temperature at transmitter for directly mounted Pt100 | 80 °C (176 °F) |
Design | |
Enclosure | Die-cast aluminum |
Shock resistance | According to EN 60068-2-29/03.95 |
Resistance to vibration | EN 60068-2-6/12.07 |
Weight | |
| 1.5 kg (3.3 lb) |
| 1.6 kg (3.5 lb) |
Dimensions (W x H x D) | See dimensional drawing |
Thread for cable gland/sensor connection | M20x1.5 other threads via adapter |
Material of the protective tube and process connection (only with pre-installed sensor tube) | Stainless steel 1.4404 (AISI 316L, UNS S 31603, X2CrNiMo17-12-2) |
Cable between transmitter and sensor element | ? 3 m for two-, three- or four-wire connections Cable resistance < 10 ? (setting range in m? 0 ... 9 999) |
Sensor break | Is recognized |
Displays and controls | |
Display (with illumination) | |
| 104 x 80 pixels |
| Can be set |
- Number of spaces after comma
| Can be set |
Setting options | - Locally with 3 buttons
- With SIMATIC PDM or HART Communicator
|
Auxiliary power | |
Battery | 3.6 V DC |
Communication | |
Wireless standard | WirelessHART V7.1 conforming |
Transmission frequency band | 2.4 GHz (ISM-Band) |
Range under reference conditions | Up to 250 m (line of sight) in outside areas Up to 50 m (greatly dependent on obstacles) in inside areas |
Communication interfaces | - HART communication with HART modem
- WirelessHART
|
Certificates and approvals | |
Wireless communication approvals | R&TTE, FCC |
General product safety | CSAUS/C, CE, UL |
Pressure Equipment Directive | This device is not covered by the pressure equipment directive; classification as per the pressure equipment directive (DGRL 2014/68/EU), Directive 1/40; Section 1, Subsection 2.1.4. |