SIMATIC WinAC RTX F

Article number

6ES7671-1RC08-0YA0

SIMATIC WINAC RTX F 2010

General information

 

Product type designation

SIMATIC WinAC RTX F 2010

Firmware version

V4.6

Engineering with

 

  • ? Programming package

STEP 7 V5.5 or higher + S7 Distributed Safety V5.4 SP5 or higher + S7 F Configuration Pack V5.5 SP6 HF1 / iMap V3.0 SP1; STEP 7 in TIA Portal V13 or higher + STEP 7 Safety Advanced V13

Memory

 

Type of memory

RAM

Work memory

 

  • ? integrated (for program)

4 Mbyte; Adjustable; depends on Non Paged Memory Pool

  • ? integrated (for data)

4 Mbyte; Adjustable; depends on Non Paged Memory Pool

Load memory

 

  • ? integrated RAM, max.

Adjustable; depends on Non Paged Memory Pool

CPU processing times

 

for bit operations, typ.

0.004 µs; Typical

for fixed point arithmetic, typ.

0.003 µs; Typical

for floating point arithmetic, typ.

0.004 µs; Typical

Reference platform

Pentium 4, 2.4 GHz

CPU-blocks

 

DB

 

  • ? Number, max.

65 535; Limited only by RAM set for data

  • ? Size, max.

64 kbyte

FB

 

  • ? Number, max.

65 536; Limited only by RAM set for code

  • ? Size, max.

64 kbyte

FC

 

  • ? Number, max.

65 536; Limited only by RAM set for code

  • ? Size, max.

64 kbyte

OB

 

  • ? Size, max.

64 kbyte

Nesting depth

 

  • ? per priority class

24

  • ? additional within an error OB

24

Counters, timers and their retentivity

 

S7 counter

 

  • ? Number

2 048

Retentivity

 

  • adjustable

Yes

  • lower limit

0

  • upper limit

2 047

  • preset

8

Counting range

 

  • can be set

Yes

  • lower limit

0

  • upper limit

999

IEC counter

 

  • ? present

Yes

  • ? Type

SFB

  • ? Number

Unlimited (limited only by RAM capacity)

S7 times

 

  • ? Number

2 048

Retentivity

 

  • adjustable

Yes

  • lower limit

0

  • upper limit

2 047

  • preset

0

Time range

 

  • lower limit

10 ms

  • upper limit

9 990 s

IEC timer

 

  • ? present

Yes

  • ? Type

SFB

  • ? Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

 

Retentivity without UPS and PS Extension Board

128 kbyte with SIMATIC IPC427C and HMI IPC477C; further SIMATIC PCs on request

Retentivity with UPS

all data

Flag

 

  • ? Number, max.

16 kbyte

  • ? Retentivity preset

MB 0 to MB 15

  • ? Number of clock memories

8

Data blocks

 

  • ? Retentivity adjustable

Yes; via non-retain property on DB

  • ? Retentivity preset

Yes

Local data

 

  • ? adjustable, max.

64 kbyte

  • ? preset

32 kbyte

  • ? per priority class, max.

61 440 byte

Address area

 

I/O address area

 

  • ? Inputs

16 kbyte

  • ? Outputs

16 kbyte

of which distributed

 

  • DP interface, inputs

16 kbyte

  • DP interface, outputs

16 kbyte

  • PROFINET interface, inputs

16 kbyte

  • PROFINET interface, outputs

16 kbyte

Process image

 

  • ? Inputs, adjustable

8 kbyte

  • ? Outputs, adjustable

8 kbyte

  • ? Inputs, default

512 byte

  • ? Outputs, default

512 byte

Subprocess images

 

  • ? Number of subprocess images, max.

15

Digital channels

 

  • ? Inputs

128 000

  • ? Outputs

128 000

Analog channels

 

  • ? Inputs

8 000

  • ? Outputs

8 000

Number of operable FMs and CPs (recommended)

 

  • ? FM

4; FM distributed: FM 350-1, FM 350-2, FM 351, FM 352 / FM 352-5, FM 353, FM 354, FM 355, FM 355-2

  • ? CP, PtP

2; CP 340, CP 341 distributed

  • ? CP, LAN

Over PC CP

Submodules

 

  • ? Number of submodules, max

4

  • of which PROFIBUS, max.

4; Supported interfaces: see 1st and 2nd interface

  • of which Industrial Ethernet, max.

1; Supported interfaces: see 3rd and 4th interface

Time of day

 

Clock

 

  • ? Hardware clock (real-time)

Yes

  • ? retentive and synchronizable

Yes

Operating hours counter

 

  • ? Number

8

Clock synchronization

 

  • ? supported

Yes

  • ? to PC-CP, slave

Yes

  • ? on Ethernet via NTP

Yes

1. Interface

 

Interface type

CP 5611-A2, CP 5621, integrated PROFIBUS interface of the SIMATIC PC

Physics

RS 485 / PROFIBUS

Isolated

Yes

Number of simultaneously operable CPs, max.

1

Power supply to interface (15 to 30 V DC), max.

does not exist

Functionality

 

  • ? MPI

No

  • ? PROFIBUS DP master

Yes

  • ? PROFIBUS DP slave

No

DP master

 

  • ? Number of connections, max.

8

  • ? Transmission rate, max.

12 Mbit/s

  • ? Number of DP slaves, max.

64

Services

 

  • PG/OP communication

Yes

  • Global data communication

No

  • S7 basic communication

No

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

  • Equidistance

Yes; Only in conjunction with isochronous mode

  • Isochronous mode

Yes

  • SYNC/FREEZE

Yes

  • Activation/deactivation of DP slaves

Yes

  • Direct data exchange (slave-to-slave communication)

Yes

  • DPV1

Yes

Address area

 

  • Inputs, max.

16 kbyte

  • Outputs, max.

16 kbyte

User data per DP slave

 

  • Inputs, max.

244 byte

  • Outputs, max.

244 byte

2. Interface

 

Interface type

CP 5613, CP 5613-A2, CP 5603, CP 5623

Physics

RS 485 / PROFIBUS

Isolated

Yes

Number of simultaneously operable CPs, max.

4

Functionality

 

  • ? MPI

No

  • ? PROFIBUS DP master

Yes

  • ? PROFIBUS DP slave

No

DP master

 

  • ? Number of connections, max.

50

  • ? Transmission rate, max.

12 Mbit/s

  • ? Number of DP slaves, max.

125

Services

 

  • PG/OP communication

Yes

  • Global data communication

No

  • S7 basic communication

No

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

  • Equidistance

Yes; Only in conjunction with isochronous mode

  • Isochronous mode

Yes

  • SYNC/FREEZE

Yes

  • Activation/deactivation of DP slaves

Yes

  • Direct data exchange (slave-to-slave communication)

Yes

  • DPV1

Yes

Address area

 

  • Inputs, max.

16 kbyte

  • Outputs, max.

16 kbyte

User data per DP slave

 

  • Inputs, max.

244 byte

  • Outputs, max.

244 byte

3. Interface

 

Interface type

PROFINET

Physics

Ethernet

Isolated

Yes

Number of simultaneously operable CPs, max.

1; Intel Pro/1000 (Intel 82571EB, 82573L, 82574L, 82541PI; non-shared IRQ required); integrated IE interface SIMATIC PC 4x7B, 6x7B, 8x7B, IPC4x7C, IPC6x7C, IPC8x7C

automatic detection of transmission rate

Yes; 10/100 Mbit/s

Autonegotiation

Yes

Autocrossing

Yes

Interface types

 

  • ? Number of ports

1

  • ? integrated switch

No

Media redundancy

 

  • ? supported

No

Functionality

 

  • ? PROFINET IO Controller

Yes

  • ? PROFINET IO Device

No

  • ? PROFINET CBA

Yes

  • ? Open IE communication

Yes

PROFINET IO Controller

 

  • ? Transmission rate, max.

100 Mbit/s

Services

 

  • PG/OP communication

Yes

  • S7 routing

Yes

  • S7 communication

Yes

  • Isochronous mode

No

  • Open IE communication

Yes

  • IRT

No

  • Prioritized startup

Yes

  • Number of IO devices with prioritized startup, max.

32

  • Number of connectable IO Devices, max.

128

  • Number of connectable IO Devices for RT, max.

128

  • of which in line, max.

128

  • Activation/deactivation of IO Devices

Yes

  • Number of IO Devices that can be simultaneously activated/deactivated, max.

8

  • IO Devices changing during operation (partner ports), supported

Yes

  • Device replacement without swap medium

Yes

  • Send cycles

1 ms

  • Updating time

1 to 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data)

Address area

 

  • Inputs, max.

16 kbyte

  • Outputs, max.

16 kbyte

  • User data per address area, max.

2 kbyte

  • User data consistency, max.

254 byte

Open IE communication

 

  • ? Number of connections, max.

32

  • ? Local port numbers used at the system end

0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535

  • ? Keep-alive function, supported

Yes

4. Interface

 

Interface type

PROFINET

Physics

Ethernet

Isolated

Yes

Number of simultaneously operable CPs, max.

1; CP 1616 (HW release 8 or above), CP 1604 (HW release 7 or higher), integrated PROFINET interface of SIMATIC PC and S7-mEC

automatic detection of transmission rate

Yes; 10/100 Mbit/s

Autonegotiation

Yes

Autocrossing

Yes

Change of IP address at runtime, supported

Yes

Interface types

 

  • ? Number of ports

3

  • ? integrated switch

Yes

Media redundancy

 

  • ? supported

Yes

  • ? Switchover time on line break, typ.

200 ms

  • ? Number of stations in the ring, max.

50

Functionality

 

  • ? PROFINET IO Controller

Yes

  • ? PROFINET IO Device

No

  • ? PROFINET CBA

Yes

  • ? Open IE communication

Yes

PROFINET IO Controller

 

  • ? Transmission rate, max.

100 Mbit/s

Services

 

  • PG/OP communication

Yes

  • S7 routing

Yes

  • S7 communication

Yes

  • Isochronous mode

Yes

  • Open IE communication

Yes

  • IRT

Yes

  • Prioritized startup

Yes

  • Number of IO devices with prioritized startup, max.

32

  • Number of connectable IO Devices, max.

256

  • Of which IO devices with IRT, max.

64

  • of which in line, max.

64

  • Number of IO Devices with IRT and the option "high flexibility"

64

  • of which in line, max.

32

  • Number of connectable IO Devices for RT, max.

256

  • of which in line, max.

256

  • Activation/deactivation of IO Devices

Yes

  • Number of IO Devices that can be simultaneously activated/deactivated, max.

8

  • IO Devices changing during operation (partner ports), supported

Yes

  • Device replacement without swap medium

Yes

  • Send cycles

250 µs, 500 µs, 1 ms

  • Updating time

0.25...512 depending on the send cycle

Address area

 

  • User data per address area, max.

2 kbyte

  • User data consistency, max.

254 byte

Open IE communication

 

  • ? Number of connections, max.

32

  • ? Local port numbers used at the system end

0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535

Isochronous mode

 

Isochronous operation (application synchronized up to terminal)

Yes

Number of DP masters with isochronous mode

2

User data per isochronous slave, max.

128 byte

Equidistance

Yes

shortest clock pulse

2.2 ms; 2.2 ms without partial process image; 2.2 ms with partial process image

Communication functions

 

PG/OP communication

Yes

Data record routing

Yes; only with CP 5611 or integrated PROFIBUS interface of the SIMATIC PC

Global data communication

 

  • ? supported

No

S7 basic communication

 

  • ? supported

No

S7 communication

 

  • ? supported

Yes

  • ? as server

Yes

  • ? as client

Yes

  • ? User data per job, max.

64 kbyte; Depends on which block is used: BSEND/USEND or PUT/GET

Open IE communication

 

  • ? TCP/IP

Yes

  • Number of connections, max.

32

  • Data length for connection type 01H, max.

Not supported

  • Data length for connection type 11H, max.

65 534 byte

  • Data length, max.

65 534 byte

  • ? ISO-on-TCP (RFC1006)

Yes

  • Number of connections, max.

32

  • Data length, max.

65 534 byte

  • ? UDP

Yes

  • Number of connections, max.

32

  • Data length, max.

1 472 byte

Web server

 

  • ? supported

Yes

  • ? Number of HTTP clients

2

  • ? User-defined websites

No

PROFINET CBA (at set setpoint communication load)

 

  • ? Setpoint for the CPU communication load

20 %

  • ? Number of remote interconnection partners

64

  • ? Number of functions, master/slave

30

  • ? Total of all master/slave connections

1 000

  • ? Data length of all incoming connections master/slave, max.

6 800 byte

  • ? Data length of all outgoing connections master/slave, max.

6 800 byte

  • ? Number of device-internal and PROFIBUS interconnections

500

  • ? Data length of device-internal und PROFIBUS interconnections, max.

4 000 byte

  • ? Data length per connection, max.

1 400 byte

Remote interconnections with acyclic transmission

 

  • Sampling frequency: Sampling time, min.

500 ms

  • Number of incoming interconnections

100

  • Number of outgoing interconnections

100

  • Data length of all incoming interconnections, max.

2 000 byte

  • Data length of all outgoing interconnections, max.

2 000 byte

  • Data length per connection, max.

1 400 byte

Remote interconnections with cyclic transmission

 

  • Transmission frequency: Transmission interval, min.

10 ms

  • Number of incoming interconnections

200

  • Number of outgoing interconnections

200

  • Data length of all incoming interconnections, max.

4 800 byte

  • Data length of all outgoing interconnections, max.

4 800 byte

  • Data length per connection, max.

250 byte

HMI variables via PROFINET (acyclic)

 

  • Number of stations that can log on for HMI variables (PN OPC/iMap)

3

  • HMI variable updating

500 ms

  • Number of HMI variables

200

  • Data length of all HMI variables, max.

2 000 byte

PROFIBUS proxy functionality

 

  • supported

Yes

  • Number of linked PROFIBUS devices

16

  • Data length per connection, max.

240 byte; Slave-dependent

Number of connections

 

  • ? overall

96

S7 message functions

 

Number of login stations for message functions, max.

62

SCAN procedure

No

Process diagnostic messages

Yes; ALARM_S, ALARM_SQ, ALARM_D, ALARM_DQ

simultaneously active Alarm-S blocks, max.

20; of a total of 20 for all SFCs

Alarm 8-blocks

Yes

  • ? Number of instances for alarm 8 and S7 communication blocks, max.

4 000

Process control messages

No

Test commissioning functions

 

Status block

Yes

Single step

Yes

Number of breakpoints

20

Status/control

 

  • ? Status/control variable

Yes

Forcing

 

  • ? Forcing

No

Diagnostic buffer

 

  • ? present

Yes

  • ? Number of entries, max.

  • adjustable

Yes

  • preset

120

Hardware requirement

 

Hardware required

PC with color monitor, keyboard, mouse or pointing device for Windows

Processor

 

  • ? Processor

Intel Celeron M 900 MHz or compatible (older PC systems with Programmable Interrupt Controllers (PIC) are not suitable for WinAC RTX F 2010.)

  • Multi-processor system

No

  • Hyper-threading

Yes

Lifetime of module

 

  • ? Main memory, min.

1 Gbyte

  • ? Required memory on hard disk

100 Mbyte

Operating systems

 

pre-installed operating system

 

  • ? Windows NT 4.0

No

  • ? Windows 2000

No

  • ? Windows Vista

No

  • ? Windows XP

Yes; Professional, SP2 and SP3

  • ? Windows XP Embedded

Yes; With the delivery image of the SIMATIC PC

  • supported HAL types under Windows XP

ACPI uniprocessor PC, ACPI multiprocessor PC, MPS multiprocessor PC

  • ? Windows 7

Yes; Professional, Enterprise, Ultimate (only 32 bits)

  • ? Windows Embedded Standard 7

No

Configuration

 

Programming

 

  • ? Nesting levels

8

Programming language

 

  • LAD

Yes

  • FBD

Yes

  • STL

Yes

  • SCL

Yes

  • CFC

Yes

  • GRAPH

Yes

  • HiGraph®

Yes

Software libraries

 

  • Easy Motion Control

Yes

Know-how protection

 

  • ? User program protection/password protection

Yes

  • ? Block encryption

No

Open Development interfaces

 

  • ? CCX (Custom Code Extension)

Yes; WinAC ODK V4.2 or higher

  • ? CMI (Controller Management Interface)

Yes; WinAC ODK V4.2 or higher

  • ? SMX (Shared Memory Extension)

Yes; WinAC ODK V4.2 or higher

  • Inputs

4 kbyte

  • Outputs

4 kbyte

Weights

 

Weight, approx.

100 g; With packaging


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ

  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà