Siemens
ÑÐÅÄÑÒÂÀ ÏÐÎÌÛØËÅÍÍÎÉ ÀÂÒÎÌÀÒÈÇÀÖÈÈ
îôèöèàëüíûé ïàðòíåð Ñèìåíñ
Êàòàëîã ÑÀ01 2017
àðõèâíûé
(4872) 700-366
skenergo@mail.ru

SIPLUS CPU 1212C

Article number

6AG1212-1AE40-4XB0

6AG1212-1AE40-2XB0

SIPLUS S7-1200 CPU 1212C DC/DC/DC

SIPLUS S7-1200 CPU 1212C DC/DC/DC

General information

 

 

Product type designation

CPU 1212C DC/DC/DC

CPU 1212C DC/DC/DC

Supply voltage

 

 

Rated value (DC)

  • ? 24 V DC

Yes

Yes

Encoder supply

 

 

24 V encoder supply

 

 

  • ? 24 V

L+ minus 4 V DC min.

L+ minus 4 V DC min.

Power loss

 

 

Power loss, typ.

9 W

9 W

Memory

 

 

Work memory

 

 

  • ? integrated

75 kbyte

75 kbyte

Load memory

 

 

  • ? integrated

1 Mbyte

1 Mbyte

  • ? Plug-in (SIMATIC Memory Card), max.

with SIMATIC memory card

with SIMATIC memory card

Backup

 

 

  • ? without battery

Yes

Yes

CPU processing times

 

 

for bit operations, typ.

0.085 µs; / instruction

0.085 µs; / instruction

for word operations, typ.

1.7 µs; / instruction

1.7 µs; / instruction

for floating point arithmetic, typ.

2.3 µs; / instruction

2.3 µs; / instruction

Data areas and their retentivity

 

 

Flag

 

 

  • ? Number, max.

4 kbyte; Size of bit memory address area

4 kbyte; Size of bit memory address area

Process image

 

 

  • ? Inputs, adjustable

1 kbyte

1 kbyte

  • ? Outputs, adjustable

1 kbyte

1 kbyte

Time of day

 

 

Clock

 

 

  • ? Hardware clock (real-time)

Yes

Yes

Digital inputs

 

 

Number of digital inputs

8; Integrated

8; Integrated

  • ? of which inputs usable for technological functions

4; HSC (High Speed Counting)

4; HSC (High Speed Counting)

Digital outputs

 

 

Number of digital outputs

6

6

  • ? of which high-speed outputs

4; 100 kHz Pulse Train Output

4; 100 kHz Pulse Train Output

Analog inputs

 

 

Number of analog inputs

2

2

Input ranges

 

 

  • ? Voltage

Yes

Yes

Analog outputs

 

 

Number of analog outputs

0

0

1. Interface

 

 

Interface type

PROFINET

PROFINET

Physics

Ethernet

Ethernet

Functionality

 

 

  • ? PROFINET IO Controller

Yes

Yes

  • ? PROFINET IO Device

Yes

Yes

  • ? Open IE communication

Yes

Yes

  • ? Web server

Yes

Yes

Communication functions

 

 

S7 communication

 

 

  • ? supported

Yes

Yes

Open IE communication

 

 

  • ? TCP/IP

Yes

Yes

  • ? ISO-on-TCP (RFC1006)

Yes

Yes

  • ? UDP

Yes

Yes

Web server

 

 

  • ? supported

Yes

Yes

Number of connections

 

 

  • ? overall

16; dynamically

16; dynamically

Integrated Functions

 

 

Number of counters

4

4

Counting frequency (counter) max.

100 kHz

100 kHz

Frequency meter

Yes

Yes

controlled positioning

Yes

Yes

Number of position-controlled positioning axes, max.

8

8

Number of positioning axes via pulse-direction interface

4; With integrated DO

4; With integrated DO

PID controller

Yes

Yes

Number of alarm inputs

4

4

Number of pulse outputs

4

4

Limit frequency (pulse)

100 kHz

100 kHz

Ambient conditions

 

 

Ambient temperature during operation

 

 

  • ? min.

-20 °C; = Tmin; Startup @ 0 °C

-40 °C; = Tmin; Startup @ -25 °C

  • ? max.

60 °C; Number of simultaneously activated inputs or outputs 4 or 3 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical

70 °C; = Tmax; Tmax > +55 °C number of simultaneously switched-on digital inputs 4, digital outputs 3, analog inputs 2 (no adjacent points) with horizontal mounting position; Tmax > +60 °C number of simultaneously switched-on digital inputs 3, digital outputs 2, analog inputs 0 (no adjacent points) with horizontal mounting position

Extended ambient conditions

 

 

  • ? relative to ambient temperature-atmospheric pressure-installation altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

 

 

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

 

 

  • against biologically active substances / conformity with EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

  • against chemically active substances / conformity with EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • against mechanically active substances / conformity with EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Configuration

 

 

Programming

 

 

Programming language

 

 

  • LAD

Yes

Yes

  • FBD

Yes

Yes

  • SCL

Yes

Yes

Dimensions

 

 

Width

90 mm

90 mm

Height

100 mm

100 mm

Depth

75 mm

75 mm

Weights

 

 

Weight, approx.

370 g

370 g


Article number

6AG1212-1BE40-4XB0

6AG1212-1BE40-2XB0

SIPLUS S7-1200 CPU 1212C AC/DC/RLY

SIPLUS S7-1200 CPU 1212C AC/DC/RLY

General information

 

 

Product type designation

CPU 1212C AC/DC/Relay

CPU 1212C AC/DC/Relay

Supply voltage

 

 

Rated value (AC)

  • ? 120 V AC

Yes

Yes

  • ? 230 V AC

Yes

Yes

Encoder supply

 

 

24 V encoder supply

 

 

  • ? 24 V

20.4 to 28.8V

20.4 to 28.8V

Power loss

 

 

Power loss, typ.

11 W

11 W

Memory

 

 

Work memory

 

 

  • ? integrated

75 kbyte

75 kbyte

Load memory

 

 

  • ? integrated

1 Mbyte

1 Mbyte

  • ? Plug-in (SIMATIC Memory Card), max.

with SIMATIC memory card

with SIMATIC memory card

Backup

 

 

  • ? without battery

Yes

Yes

CPU processing times

 

 

for bit operations, typ.

0.085 µs; / Operation

0.085 µs; / Operation

for word operations, typ.

1.7 µs; / Operation

1.7 µs; / Operation

for floating point arithmetic, typ.

2.3 µs; / Operation

2.3 µs; / Operation

Data areas and their retentivity

 

 

Flag

 

 

  • ? Number, max.

4 kbyte; Size of bit memory address area

4 kbyte; Size of bit memory address area

Process image

 

 

  • ? Inputs, adjustable

1 kbyte

1 kbyte

  • ? Outputs, adjustable

1 kbyte

1 kbyte

Time of day

 

 

Clock

 

 

  • ? Hardware clock (real-time)

Yes

Yes

Digital inputs

 

 

Number of digital inputs

8; Integrated

8; Integrated

  • ? of which inputs usable for technological functions

4; HSC (High Speed Counting)

4; HSC (High Speed Counting)

Digital outputs

 

 

Number of digital outputs

6; Relays

6; Relays

Analog inputs

 

 

Number of analog inputs

2

2

Input ranges

 

 

  • ? Voltage

Yes

Yes

Analog outputs

 

 

Number of analog outputs

0

0

1. Interface

 

 

Interface type

PROFINET

PROFINET

Physics

Ethernet

Ethernet

Functionality

 

 

  • ? PROFINET IO Controller

Yes

Yes

  • ? PROFINET IO Device

Yes

Yes

  • ? Open IE communication

Yes

Yes

  • ? Web server

Yes

Yes

Communication functions

 

 

S7 communication

 

 

  • ? supported

Yes

Yes

Open IE communication

 

 

  • ? TCP/IP

Yes

Yes

  • ? ISO-on-TCP (RFC1006)

Yes

Yes

  • ? UDP

Yes

Yes

Web server

 

 

  • ? supported

Yes

Yes

Number of connections

 

 

  • ? overall

16; dynamically

16; dynamically

Integrated Functions

 

 

Number of counters

4

4

Counting frequency (counter) max.

100 kHz

100 kHz

Frequency meter

Yes

Yes

controlled positioning

Yes

Yes

Number of position-controlled positioning axes, max.

8

8

Number of positioning axes via pulse-direction interface

Up to 4 with SB 1222

PID controller

Yes

Yes

Number of alarm inputs

4

4

Ambient conditions

 

 

Ambient temperature during operation

 

 

  • ? min.

-20 °C; = Tmin; Startup @ 0 °C

-40 °C; = Tmin; Startup @ -25 °C

  • ? max.

60 °C; Number of simultaneously activated inputs or outputs 4 or 3 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical

70 °C; = Tmax; Tmax > +55 °C number of simultaneously switched-on digital inputs 4, digital outputs 3, analog inputs 2 (no adjacent points) with horizontal mounting position; Tmax > +60 °C number of simultaneously switched-on digital inputs 3, digital outputs 2, analog inputs 0 (no adjacent points) with horizontal mounting position

Extended ambient conditions

 

 

  • ? relative to ambient temperature-atmospheric pressure-installation altitude

Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); from 2 000 m max. 132 V AC

Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); from 2 000 m max. 132 V AC

Relative humidity

 

 

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

 

 

  • against biologically active substances / conformity with EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

  • against chemically active substances / conformity with EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • against mechanically active substances / conformity with EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Configuration

 

 

Programming

 

 

Programming language

 

 

  • LAD

Yes

Yes

  • FBD

Yes

Yes

  • SCL

Yes

Yes

Dimensions

 

 

Width

90 mm

90 mm

Height

100 mm

100 mm

Depth

75 mm

75 mm

Weights

 

 

Weight, approx.

425 g

425 g


Article number

6AG1212-1HE40-4XB0

6AG1212-1HE40-2XB0

SIPLUS S7-1200 CPU 1212C DC/DC/RLY

SIPLUS S7-1200 CPU 1212C DC/DC/RLY

General information

 

 

Product type designation

CPU 1212C DC/DC/Relay

CPU 1212C DC/DC/Relay

Supply voltage

 

 

Rated value (DC)

  • ? 24 V DC

Yes

Yes

Encoder supply

 

 

24 V encoder supply

 

 

  • ? 24 V

L+ minus 4 V DC min.

L+ minus 4 V DC min.

Power loss

 

 

Power loss, typ.

9 W

9 W

Memory

 

 

Work memory

 

 

  • ? integrated

75 kbyte

75 kbyte

Load memory

 

 

  • ? integrated

1 Mbyte

1 Mbyte

  • ? Plug-in (SIMATIC Memory Card), max.

with SIMATIC memory card

with SIMATIC memory card

Backup

 

 

  • ? without battery

Yes

Yes

CPU processing times

 

 

for bit operations, typ.

0.085 µs; / instruction

0.085 µs; / instruction

for word operations, typ.

1.7 µs; / instruction

1.7 µs; / instruction

for floating point arithmetic, typ.

2.3 µs; / instruction

2.3 µs; / instruction

Data areas and their retentivity

 

 

Flag

 

 

  • ? Number, max.

4 kbyte; Size of bit memory address area

4 kbyte; Size of bit memory address area

Process image

 

 

  • ? Inputs, adjustable

1 kbyte

1 kbyte

  • ? Outputs, adjustable

1 kbyte

1 kbyte

Time of day

 

 

Clock

 

 

  • ? Hardware clock (real-time)

Yes

Yes

Digital inputs

 

 

Number of digital inputs

8; Integrated

8; Integrated

  • ? of which inputs usable for technological functions

4; HSC (High Speed Counting)

4; HSC (High Speed Counting)

Digital outputs

 

 

Number of digital outputs

6; Relays

6; Relays

Analog inputs

 

 

Number of analog inputs

2

2

Input ranges

 

 

  • ? Voltage

Yes

Yes

Analog outputs

 

 

Number of analog outputs

0

0

1. Interface

 

 

Interface type

PROFINET

PROFINET

Physics

Ethernet

Ethernet

Functionality

 

 

  • ? PROFINET IO Controller

Yes

Yes

  • ? PROFINET IO Device

Yes

Yes

  • ? Open IE communication

Yes

Yes

  • ? Web server

Yes

Yes

Communication functions

 

 

S7 communication

 

 

  • ? supported

Yes

Yes

Open IE communication

 

 

  • ? TCP/IP

Yes

Yes

  • ? ISO-on-TCP (RFC1006)

Yes

Yes

  • ? UDP

Yes

Yes

Web server

 

 

  • ? supported

Yes

Yes

Number of connections

 

 

  • ? overall

16; dynamically

16; dynamically

Integrated Functions

 

 

Number of counters

4

4

Counting frequency (counter) max.

100 kHz

100 kHz

Frequency meter

Yes

Yes

controlled positioning

Yes

Yes

Number of position-controlled positioning axes, max.

8

8

Number of positioning axes via pulse-direction interface

Up to 4 with SB 1222

PID controller

Yes

Yes

Number of alarm inputs

4

4

Ambient conditions

 

 

Ambient temperature during operation

 

 

  • ? min.

-20 °C; = Tmin; Startup @ 0 °C

-40 °C; = Tmin; Startup @ -25 °C

  • ? max.

60 °C; Number of simultaneously activated inputs or outputs 4 or 3 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical

70 °C; = Tmax; Tmax > +55 °C number of simultaneously switched-on digital inputs 4, digital outputs 3, analog inputs 2 (no adjacent points) with horizontal mounting position; Tmax > +60 °C number of simultaneously switched-on digital inputs 3, digital outputs 2, analog inputs 0 (no adjacent points) with horizontal mounting position

Extended ambient conditions

 

 

  • ? relative to ambient temperature-atmospheric pressure-installation altitude

Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); from 2 000 m max. 132 V AC

Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); from 2 000 m max. 132 V AC

Relative humidity

 

 

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

 

 

  • against biologically active substances / conformity with EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

  • against chemically active substances / conformity with EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • against mechanically active substances / conformity with EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Configuration

 

 

Programming

 

 

Programming language

 

 

  • LAD

Yes

Yes

  • FBD

Yes

Yes

  • SCL

Yes

Yes

Dimensions

 

 

Width

90 mm

90 mm

Height

100 mm

100 mm

Depth

75 mm

75 mm

Weights

 

 

Weight, approx.

385 g

385 g


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
Êàòàëîã îáîðóäîâàíèÿ 2017
Siemens Industry Catalog Drive Technology Automation Technology Automation Systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial Communication Introduction Industrial Ethernet PROFINET Introduction Drive Systems Controller Modular controllers SIMATIC S7-1200 Central processing units CPU 1211C SIPLUS CPU 1211C CPU 1212C SIPLUS CPU 1212C CPU 1214C SIPLUS CPU 1214C CPU 1215C SIPLUS CPU 1215C CPU 1217C SIMATIC S7-1500 SIMATIC S7-300 SIMATIC S7-400 Distributed controllers PC-based controllers Embedded Controller Embedded bundles Communication for SIMATIC S7-1500 System interfacing / SIMATIC S7 / Communication for SIMATIC S7-300 System interfacing / SIMATIC S7 / Communication for SIMATIC S7-400 System interfacing for PG/PC/IPC / Communication for PC-based systems SIMATIC PCS 7 process control systems Distributed I/O Motion Control Systems CNC Controls Operator panels Industrial PC Switching and Protection Devices for Power Distribution Power Monitoring SENTRON Measuring Devices Configuring, Visualizing and Controlling with SIMATIC Configuring, Visualizing and Controlling with SENTRON Industrial Identification Systems Network Components Industrial Controls SITOP power supplies Software and Tools Network management and diagnostics Technology Components PROFIBUS AS-Interface IO-Link Industrial Wireless Communication Industrial Remote Communication Industrial Security Industrial Controls Manufacturing Execution Systems (MES) SIMATIC IT PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supplies Products for specific requirements Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services ... and everything else you need




  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà