General information | | | | |
Product type designation | SM 1221 DI 8x24 VDC | SM 1221 DI 8x24 VDC | SM 1221 DI 16x24 VDC | SM 1221 DI 16x24 VDC |
Supply voltage | | | | |
Rated value (DC) | | | | |
| Yes | Yes | Yes | Yes |
Input current | | | | |
from backplane bus 5 V DC, max. | 105 mA | 105 mA | 130 mA | 130 mA |
Digital inputs | | | | |
| 4 mA; per channel | 4 mA; per channel | 4 mA; per channel | 4 mA; per channel |
Output voltage | | | | |
Power supply to the transmitters | | | | |
| Yes | Yes | Yes | Yes |
Power loss | | | | |
Power loss, typ. | 1.5 W | 1.5 W | 2.5 W | 2.5 W |
Digital inputs | | | | |
Number of digital inputs | 8 | 8 | 16 | 16 |
| 2 | 2 | 4 | 4 |
Input characteristic curve in accordance with IEC 61131, type 1 | Yes | Yes | Yes | Yes |
Number of simultaneously controllable inputs | | | | |
all mounting positions | | | | |
| 8 | 8 | 16 | 16 |
horizontal installation | | | | |
| 8 | 8 | 16 | 16 |
| 8 | 8 | 16 | 16 |
vertical installation | | | | |
| 8 | 8 | 16 | 16 |
Input voltage | | | | |
| DC | DC | DC | DC |
| 24 V | 24 V | 24 V | 24 V |
| 5 V DC at 1 mA | 5 V DC at 1 mA | 5 V DC at 1 mA | 5 V DC at 1 mA |
| 15 V DC at 2.5 mA | 15 V DC at 2.5 mA | 15 V DC at 2.5 mA | 15 V DC at 2.5 mA |
Input current | | | | |
| 1 mA | 1 mA | 1 mA | 1 mA |
| 2.5 mA | 2.5 mA | 2.5 mA | 2.5 mA |
| 4 mA | 4 mA | 4 mA | 4 mA |
Input delay (for rated value of input voltage) | | | | |
for standard inputs | | | | |
| Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
for interrupt inputs | | | | |
| Yes | Yes | Yes | Yes |
Cable length | | | | |
| 500 m | 500 m | 500 m | 500 m |
| 300 m | 300 m | 300 m | 300 m |
Interrupts/diagnostics/status information | | | | |
Alarms | Yes | Yes | Yes | Yes |
Diagnostic functions | Yes | Yes | Yes | Yes |
Alarms | | | | |
| Yes | Yes | Yes | Yes |
Diagnostic messages | | | | |
| Yes | Yes | Yes | Yes |
Diagnostics indication LED | | | | |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Potential separation | | | | |
Potential separation digital inputs | | | | |
| 2 | 2 | 4 | 4 |
Degree and class of protection | | | | |
Degree of protection acc. to EN 60529 | | | | |
| Yes | Yes | Yes | Yes |
Standards, approvals, certificates | | | | |
CE mark | Yes | Yes | Yes | Yes |
Ambient conditions | | | | |
Free fall | | | | |
| 0.3 m; five times, in product package | 0.3 m; five times, in product package | 0.3 m; five times, in product package | 0.3 m; five times, in product package |
Ambient temperature during operation | | | | |
| -40 °C; = Tmin; Startup @ -25 °C | -20 °C; = Tmin; Startup @ 0 °C | -40 °C; = Tmin; Startup @ -25 °C | -20 °C; = Tmin; Startup @ 0 °C |
| 70 °C; = Tmax; Tmax > +60 °C number of simultaneously activated inputs 4 (no adjacent points) for horizontal mounting position | 60 °C; = Tmax | 70 °C; = Tmax; Tmax > +60 °C number of simultaneously activated inputs 8 (no adjacent points) for horizontal mounting position | 60 °C; = Tmax |
Extended ambient conditions | | | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | | | | |
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance | | | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Connection method | | | | |
required front connector | Yes | Yes | Yes | Yes |
Mechanics/material | | | | |
Enclosure material (front) | | | | |
| Yes | Yes | Yes | Yes |
Dimensions | | | | |
Width | 45 mm | 45 mm | 45 mm | 45 mm |
Height | 100 mm | 100 mm | 100 mm | 100 mm |
Depth | 75 mm | 75 mm | 75 mm | 75 mm |
Weights | | | | |
Weight, approx. | 170 g | 170 g | 210 g | 210 g |