Product designation | | - | HCS300I current detection module 2.4-25A | HCS300I current detection module 10-100A | HCS300I current detection module 20-200A | HCS300I I/U detection module I=2.4-25A | HCS300I I/U detection module I=10-100A | HCS300I I/U detection module I=20-200A | HCS300I decoupling module |
Certificates/ approvals: | | | | | | | | | | | | |
Certificate of suitability | | CE, cULus, C-Tick (RCM) |
Supply voltage: | | | | | | | | | | | | |
Supply voltage at AC rated value | V | - |
Relative negative tolerance of the supply voltage | % | 15 | - |
Relative positive tolerance of the supply voltage | % | 20 | - |
Supply voltage frequency | | | | | | | | | | | | |
| Hz | - |
| Hz | - |
Relative symmetrical tolerance of the supply voltage frequency | % | - |
Communication: | | | | | | | | | | | | |
Design of the interface | | PROFIBUS DP | system interface |
Installation/ mounting/ dimensions: | | | | | | | | | | | | |
Mounting position | | any |
Mounting type | | Snap-mounting on a TH 35 mm standard rail compliant with IEC 60715 or screw-mounted using additional push-in lug |
Type of ventilation | | - |
Shock resistance acc. to IEC 60068-2-27 | | 15g / 11 ms |
Vibration resistance | | | | | | | | | | | | |
| | 5 ... 500 Hz, 3.5 mm amplitude, 1 g, 10 cycles, 1 octave/min |
| | - |
Protection class IP | | IP20 |
Width | mm | 45 | 22.5 | 45 | 55 | 120 | 45 | 55 | 120 | 22.5 |
Height | mm | 106 | 92 | 102 | 84 | 94 | 95 | 85 | 94 | 95 | 92 |
Depth | mm | 115 | 45 | 72 | 145 | 71 | 97 | 145 | 115 |
Electromagnetic compatibility: | | | | | | | | | | | | |
Conducted interference due to burst acc. to IEC 61000-4-4 | | 2 kV power supply lines / 1 kV signal lines |
Conducted interference due to surge acc. to IEC 61000-4-5 | | on supply cables: 1 kV symmetrical, 2 kV asymmetrical; on signal cables > 30 m unshielded: 1 kV symmetrical, 2 kV asymmetrical, > 30 m unshielded: 2 kV asymmetrical | on power supply lines: 1 kV symmetric, 2 kV asymmetric, on signal lines > 30 m unshielded: 1 kV symmetric, 2 kV asymmetric, > 30 m shielded: 2 kV asymmetric | on power supply lines: 1 kV symmetric, 2 kV asymmetric;
on signal lines > 30 m unshielded: 1 kV symmetric, 2 kV asymmetric, > 30 m shielded: 2 kV asymmetric |
Conducted interference due to high-frequency radiation acc. to IEC 61000-4-6 | | 10 V (0.15 ... 80 MHz) |
Electrostatic discharge acc. to IEC 61000-4-2 | | 6 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling acc. to IEC 61000-4-3 | | 10 V/m (80 ... 1000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz) |
EMC emitted interference | | IEC61131: Class A; conducted and radiated: DIN EN 55011/CISPR11 (corresponds to degree of severity A) |
Overvoltage category | | - | III | - |
Ambient conditions: | | | | | | | | | | | | |
Ambient temperature | | | | | | | | | | | | |
| °C | -25 ... +60 |
| °C | -40 ... +80 |
| °C | -40 ... +80 |
Air pressure | | | | | | | | | | | | |
| hPa | 795 ... 1 080 |
| hPa | 660 ... 1 080 |
Relative humidity at 25 °C maximum | % | - |
Installation altitude at height above sea level maximum | m | 2 000 |