Siemens
ÑÐÅÄÑÒÂÀ ÏÐÎÌÛØËÅÍÍÎÉ ÀÂÒÎÌÀÒÈÇÀÖÈÈ
îôèöèàëüíûé ïàðòíåð Ñèìåíñ
Êàòàëîã ÑÀ01 2017
àðõèâíûé
(4872) 700-366
skenergo@mail.ru

Media modules for modular SCALANCE X-300 managed

Order number

6GK5992-2GA00-8AA0

6GK5992-2GA00-8FA0

6GK5992-2SA00-8AA0

Product type designation

MM992-2CUC

MM992-2CUC

MM992-2CU

Interfaces

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

2

2

2

Number of electrical connections

 

 

 

  • ? for network components or terminal equipment maximum

2

2

2

Number of 10/100/1000 Mbit/s RJ45 ports

2

2

2

Type of electrical connection

 

 

 

  • ? for network components or terminal equipment

RJ45

RJ45

RJ45

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during storage

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during transport

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

Relative humidity at 25 °C without condensation during operation maximum

95 %

95 %

95 %

Ambient condition for operation

Conformal coating, yes

Protection class IP

IP20

IP20

IP20

Design, dimensions and weight

 

 

 

Design

Media module with retaining collar

Media module with retaining collar

Media module

Width

60 mm

60 mm

60 mm

Height

22 mm

22 mm

22 mm

Depth

100 mm

100 mm

100 mm

Net weight

0.08 kg

0.08 kg

0.08 kg

Mounting type

latched

latched

latched

  • ? Installation in media module slot

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Standard

 

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • ? for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

  • ? KC approval

Yes

Yes

Yes

  • ? Railway application in accordance with EN 50155

Yes

  • ? Railway application in accordance with EN 50121-4

Yes

  • ? Fire protection in accordance with EN 45545-2

Yes

MTBF at 40 °C

250 y

250 y

250 y


Order number

6GK5992-2HA00-0AA0

6GK5992-2VA00-8AA0

Product type designation

MM992-2 M12 GIGA

MM992-2VD (RJ45)

Suitability for use

Ethernet communication via two wire cable

Suitability for operation

SCALANCE X308-2M, XR324-12M, S627-2M

Interfaces

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

2

2

Number of electrical connections

 

 

  • ? for network components or terminal equipment maximum

2

2

Number of 10/100/1000 Mbit/s M12 ports

2

Number of 10/100/1000 Mbit/s RJ45 ports

2

Type of electrical connection

 

 

  • ? for network components or terminal equipment

M12

RJ45

Number of 1000 Mbit/s SC ports (SX)

2

Operating mode

 

 

  • ? Standard Ethernet

Yes

  • ? VD

Yes

Wire length

 

 

  • ? for Standard Ethernet mode maximum

100 m

  • ? of IE FC Standard Cable GP 4x2, AWG24, Cat6 for VD mode

 

 

  • at 100 Mbit/s maximum

500 m

  • ? of IE FC Standard Cable GP 2x2, AWG22, Cat5e for VD mode

 

 

  • at 10 Mbit/s maximum

500 m

  • at 100 Mbit/s maximum

300 m

  • ? of PB FC Standard Cable GP for VD mode

 

 

  • at 10 Mbit/s maximum

1 000 m

  • at 100 Mbit/s maximum

100 m

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

  • ? during storage

-40 ... +85 °C

-40 ... +85 °C

  • ? during transport

-40 ... +85 °C

-40 ... +85 °C

Relative humidity at 25 °C without condensation during operation maximum

95 %

95 %

Ambient condition for operation

Conformal coating, yes

Protection class IP

IP20

IP20

Design, dimensions and weight

 

 

Design

Media module

Media module with retaining collar

Width

60 mm

60 mm

Height

22 mm

22 mm

Depth

100 mm

100 mm

Net weight

0.08 kg

0.08 kg

Mounting type

latched

latched

  • ? Installation in media module slot

Yes

Yes

Standards, specifications, approvals

 

 

Standard

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

  • ? for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

  • ? C-Tick

Yes

Yes

  • ? KC approval

Yes

Yes

  • ? Railway application in accordance with EN 50155

Yes

  • ? Railway application in accordance with EN 50121-4

Yes

  • ? Fire protection in accordance with EN 45545-2

Yes

MTBF at 40 °C

250 y

250 y


Order number

6GK5991-2AB00-8AA0

6GK5991-2AC00-8AA0

6GK5991-2AB01-8AA0

Product type designation

MM991-2 (BFOC)

MM991-2LD (BFOC)

MM991-2FM

Interfaces

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

2

2

2

Number of optical interfaces for network components or terminal equipment maximum

2

2

2

Number of 100 Mbit/s ST(BFOC) ports for multimode Integrated

2

2

2

Design of the optical interface for network components or terminal equipment

ST/BFOC

ST/BFOC

ST/BFOC

Wavelength of the optical interface

1 310 nm; Multi-mode

1 310 nm; Single-mode

1 310 nm; Multi-mode

Connectable optical power relative to 1 mW

 

 

 

  • ? of the transmitter output minimum

-19 dB

-15 dB

-19 dB

  • ? of the transmitter output maximum

-14 dB

-8 dB

-14 dB

  • ? of the receiver input maximum

-3 dB

-3 dB

-3 dB

Optical sensitivity relating to 1 mW of the receiver input minimum

-32 dB

-34 dB

-32 dB

Damping ratio of the FOC transmission link minimum necessary

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 ... 5 km

0 ... 26 km

0 ... 5 km

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during storage

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during transport

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

Relative humidity at 25 °C without condensation during operation maximum

95 %

95 %

95 %

Protection class IP

IP20

IP20

IP20

Design, dimensions and weight

 

 

 

Design

Media module

Media module

Media module

Width

60 mm

60 mm

60 mm

Height

22 mm

22 mm

22 mm

Depth

100 mm

100 mm

100 mm

Net weight

0.08 kg

0.08 kg

0.08 kg

Mounting type

latched

latched

latched

  • ? Installation in media module slot

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Standard

 

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, II 3(2) G Ex nA [op is] IIC T4 DEKRA 11 ATEX 0060 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3(2) G Ex nA [op is] IIC T4 DEKRA 11 ATEX 0060 X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • ? for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

  • ? KC approval

Yes

Yes

Yes

MTBF at 40 °C

140 y

115 y

135 y


Order number

6GK5991-2AD00-8AA0

6GK5991-2AF00-8AA0

6GK5991-2AE00-8AA0

6GK5991-2AH00-8AA0

Product type designation

MM991-2 (SC)

MM991-2LD (SC)

MM991-2LH+

MM991-2P (SC RJ)

Interfaces

 

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

2

2

2

2

Number of optical interfaces for network components or terminal equipment maximum

2

2

2

2

Number of 100 Mbit/s SC ports for multimode Integrated

2

2

2

0

number of 100 Mbit/s SC-RJ-ports

2

Design of the optical interface for network components or terminal equipment

SC

SC

SC

SC RJ

Wavelength of the optical interface

1 310 nm; Multi-mode

1 310 nm; Single-mode

1 550 nm; Single-mode

650 nm; POF/PCF

Connectable optical power relative to 1 mW

 

 

 

 

  • ? of the transmitter output minimum

-19 dB

-15 dB

-5 dB

-8 dB

  • ? of the transmitter output maximum

-14 dB

-8 dB

0 dB

-2 dB

  • ? of the receiver input maximum

-3 dB

-3 dB

-3 dB

1 dB

Optical sensitivity relating to 1 mW of the receiver input minimum

-34 dB

-32 dB

-34 dB

23 dB

Damping ratio of the FOC transmission link minimum necessary

0 dB

0 dB

3 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 ... 5 km

0 ... 26 km

12 ... 70 km

0.001 ... 0.1 km

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +60 °C

-25 ... +40 °C

  • ? during storage

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during transport

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

Relative humidity at 25 °C without condensation during operation maximum

95 %

95 %

95 %

95 %

Protection class IP

IP20

IP20

IP20

IP20

Design, dimensions and weight

 

 

 

 

Design

Media module

Media module

Media module

Media module

Width

60 mm

60 mm

60 mm

60 mm

Height

22 mm

22 mm

22 mm

22 mm

Depth

100 mm

100 mm

100 mm

100 mm

Net weight

0.08 kg

0.08 kg

0.08 kg

0.08 kg

Mounting type

latched

latched

latched

latched

  • ? Installation in media module slot

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • ? for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

Yes

  • ? KC approval

Yes

Yes

Yes

Yes

MTBF at 40 °C

140 y

115 y

105 y

230 y


Order number

6GK5992-2AL00-8AA0

6GK5992-2AL00-8FA0

6GK5992-2AM00-8AA0

6GK5992-2AN00-8AA0

Product type designation

MM992-2

MM992-2

MM992-2LD

MM992-2LH

Interfaces

 

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

2

2

2

2

Number of optical interfaces for network components or terminal equipment maximum

2

2

2

2

Number of 1000 Mbit/s SC ports (LX)

2

2

Number of 1000 Mbit/s SC ports (SX)

2

2

Design of the optical interface for network components or terminal equipment

SC

SC

SC

SC

Wavelength of the optical interface

850 nm; Multi-mode

850 nm; Multi-mode

1 310 nm; Single-mode

1 550 nm; Single-mode

Connectable optical power relative to 1 mW

 

 

 

 

  • ? of the transmitter output minimum

-9.5 dB

-9.5 dB

-9.5 dB

-6 dB

  • ? of the transmitter output maximum

-4 dB

-4 dB

-3 dB

0 dB

  • ? of the receiver input maximum

-3 dB

-3 dB

-3 dB

-3 dB

Optical sensitivity relating to 1 mW of the receiver input minimum

-17 dB

-17 dB

-21 dB

-23 dB

Damping ratio of the FOC transmission link minimum necessary

0 dB

0 dB

0 dB

3 dB

Range at the optical interface depending on the optical fiber used

0 ... 0.75 km

0 ... 0.75 km

0 ... 10 km

8 ... 40 km

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +60 °C

  • ? during storage

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during transport

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

Relative humidity at 25 °C without condensation during operation maximum

95 %

95 %

95 %

95 %

Ambient condition for operation

Conformal coating, yes

Protection class IP

IP20

IP20

IP20

IP20

Design, dimensions and weight

 

 

 

 

Design

Media module

Media module

Media module

Media module

Width

60 mm

60 mm

60 mm

60 mm

Height

22 mm

22 mm

22 mm

22 mm

Depth

100 mm

100 mm

100 mm

100 mm

Net weight

0.08 kg

0.08 kg

0.08 kg

0.08 kg

Mounting type

latched

latched

latched

latched

  • ? Installation in media module slot

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • ? for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

Yes

  • ? KC approval

Yes

Yes

Yes

Yes

  • ? Railway application in accordance with EN 50155

Yes

  • ? Railway application in accordance with EN 50121-4

Yes

  • ? Fire protection in accordance with EN 45545-2

Yes

MTBF at 40 °C

55 y

55 y

55 y

55 y


Order number

6GK5992-2AP00-8AA0

6GK5992-2AQ00-8AA0

6GK5992-2AS00-8AA0

Product type designation

MM992-2LH+

MM992-2ELH

MM992-2SFP

Interfaces

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

2

2

2

Number of electrical connections

 

 

 

  • ? for SFP plug-in

2

Number of optical interfaces for network components or terminal equipment maximum

2

2

Number of 1000 Mbit/s SC ports (LX)

2

2

Design of the optical interface for network components or terminal equipment

SC

SC

Wavelength of the optical interface

1 550 nm; Single-mode

1 550 nm; Single-mode

Connectable optical power relative to 1 mW

 

 

 

  • ? of the transmitter output minimum

0 dB

0 dB

  • ? of the transmitter output maximum

5 dB

5 dB

  • ? of the receiver input maximum

-3 dB

-3 dB

Optical sensitivity relating to 1 mW of the receiver input minimum

-23 dB

-30 dB

Damping ratio of the FOC transmission link minimum necessary

8 dB

8 dB

Range at the optical interface depending on the optical fiber used

30 ... 70 km

37 ... 120 km

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • ? during operation

-40 ... +60 °C

-40 ... +60 °C

-40 ... +70 °C

  • ? during storage

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

  • ? during transport

-40 ... +85 °C

-40 ... +85 °C

-40 ... +85 °C

Relative humidity at 25 °C without condensation during operation maximum

95 %

95 %

95 %

Protection class IP

IP20

IP20

IP20

Design, dimensions and weight

 

 

 

Design

Media module

Media module

Media module

Width

60 mm

60 mm

60 mm

Height

22 mm

22 mm

22 mm

Depth

100 mm

100 mm

100 mm

Net weight

0.08 kg

0.08 kg

0.08 kg

Mounting type

latched

latched

latched

  • ? Installation in media module slot

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Standard

 

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • ? for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

  • ? KC approval

Yes

Yes

Yes

MTBF at 40 °C

55 y

55 y

250 y


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
Êàòàëîã îáîðóäîâàíèÿ 2017
Siemens Industry Catalog Drive Technology Automation Technology Automation Systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial Communication Introduction Industrial Ethernet PROFINET Introduction Drive Systems Controller SIMATIC PCS 7 process control systems Distributed I/O Motion Control Systems CNC Controls Operator panels Industrial PC Switching and Protection Devices for Power Distribution Power Monitoring SENTRON Measuring Devices Configuring, Visualizing and Controlling with SIMATIC Configuring, Visualizing and Controlling with SENTRON Industrial Identification Systems Network Components Cabling Technology Layer 2 Switches Compact Switch Modules SCALANCE X-000 unmanaged SCALANCE X-100 unmanaged SCALANCE X-200 managed SCALANCE X-200IRT managed SCALANCE X-300 managed SCALANCE X-300 managed SIPLUS SCALANCE X-300 managed SCALANCE XR-300 managed SCALANCE X-300PoE managed SCALANCE XR-300PoE managed SCALANCE X-300EEC managed SCALANCE XR-300EEC managed Media modules for modular SCALANCE X-300 managed SCALANCE X-500 managed Industrial Ethernet Security Industrial Wireless LAN Network transitions Industrial Controls SITOP power supplies Software and Tools Network management and diagnostics Technology Components PROFIBUS AS-Interface IO-Link Industrial Wireless Communication Industrial Remote Communication Industrial Security Industrial Controls Manufacturing Execution Systems (MES) SIMATIC IT PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supplies Products for specific requirements Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services ... and everything else you need




  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà