SIMATIC HMI device with an installed Runtime option of WinCC flexible /Sm@rtService or /Sm@rtAccess. For further information on WinCC flexible and the Sm@rt options, see http://www.siemens.com/simatic-wincc-flexible
TS Adapter II
Main features of TS Adapter II:
Single-width standard S7-300 housing
Mounted onto DIN or S7-profile rail, therefore no time-consuming cabinet installation required using a mounting plate
Integral modem, either analog or ISDN as required
USB interface for parameterization. This interface can also be used locally as a programming interface for the connected devices
Serial RS232 interface for connecting external modems (e.g. wireless modem)
Firmware with update capability
Power supply over MPI or over external 24 V power supply
Connection of an external modem, e.g. a GSM wireless modem, over serial interface
Can be connected to:
MPI
PROFIBUS DP up to 12 Mbit/s (previously 1.5 Mbit/s)
PPI
Scope of delivery:
The following components are supplied with the TS Adapter II:
DVD with driver
TeleService software V6.1 (Can be used for 14 days). For further operation, a license is required)
MPI cable, 0.8 m, for connecting the adapter to the MPI/DP interface
Standard telephone cable, 3 m, with RJ12 connectors (only for TS Adapter II modem)
Standard telephone cable, 3 m, with RJ45 connectors (only for ISDN TS Adapter II)
TAE6N plug (only for TS Adapter II modem)
When using the TS Adapter II modem outside Germany, a standard national telephone plug can be snapped onto the RJ12 connector. A TAE6N connector is supplied for Germany. In some countries, telephone sockets with RJ12 sockets are available, in which case telephone cables can be used without the need for a telephone plug.
For operation, TeleService Software Version 6.0 is required.
TS Adapter IE
Main features of TS Adapter IE:
Single-width standard S7-300 housing
Mounting on DIN or S7 rail
Integral modem, either analog or ISDN as required
Firmware with update capability
Power supply over external 24 V power supply
Serial interface for connection of an external modem, e.g. a GSM wireless modem
An RJ45 Ethernet interface (10/100 Mbit/s)
Industry-compatible in accordance with SIMATIC standard
Parameterization:
The TS Adapter IE can be parameterized locally or over a remote link. TeleService software V6.1 or an Internet browser is used for this purpose.
The firewall is parameterized easily by selecting and deselecting the appropriate services with a click of the mouse button. In "expert mode", the adapter can also be parameterized like a standard router.
Security:
Only dial-in access is possible: The service engineer dials into the adapter using a supplied telephone number. Authentication is performed by means of a user log-in with a password and Challenge Handshake Authentication Protocol (CHAP). Up to 8 user accounts can be created with different log-ins and passwords.
As an option, e.g. for security reasons or to save telephone charges, the TS Adapter IE will interrupt the connection following correct authentication and call the user back on the telephone number stored in the TS Adapter IE.
The implemented firewall protects the plant from unauthorized access over the Internet. By default, the firewall only permits S7 communication. The required services, e.g. Sm@rt-Access, Sm@rt-Service or PCAnywhere, can be individually enabled during parameterization. For sending e-mails, it is necessary to enable the SMTP protocol and to set the parameters for outgoing calls. It is also possible to block all incoming data packets during connection to the Internet.
Scope of delivery:
The following components are supplied with the TS Adapter IE:
CD with drivers and TeleService V 6.1 software (can be used for 2 weeks without a license) including standard software for sending e-mails from S7 CPUs
Standard telephone cable, 3 m, with RJ12 connectors (only for TS Adapter IE modem)
Standard telephone cable, 3 m, with RJ45 connectors (only for ISDN TS Adapter IE)
TAE6N plug (only for TS Adapter IE modem)
When using the analog TS Adapter IE outside Germany, a standard country-specific telephone plug can be snapped onto the RJ12 connector. A TAE6N connector is supplied for Germany. In some countries, telephone sockets with RJ12 sockets are available, in which case telephone cables can be used without the need for a telephone plug.
TS Adapter IE Basic
The TS Adapter IE Basic in SIMATIC S7-1200 design is optimized for operation with SIMATIC S7-1200. It can also be used with S7-300 and S7-400. The adapter has a modular design and comprises the following:
Basic unit TS Adapter IE Basic
TS module
TS module modem: Contains an analog modem for the connection to the analog telephone network
TS module ISDN: Contains a terminal adapter for the connection to the ISDN network
TS module RS232: With RS232 interface for connecting an external modem
TS module GSM: Contains a wireless modem for connecting to the GSM/GPRS network
Only the combination of a basic unit TS Adapter IE Basic and a TS module forms a complete functional unit (total unit). Basic unit and TS module are connected via a connector and assembled together.
The functions of the TS Adapter are implemented in the basic unit. The basic unit has an Ethernet interface for connecting to PGs, PCs, or automation system. The basic unit is supplied with 24 V DC and grounded via a socket board.
The TS modules form the electrical interface to the telephone network. They are supplied with electricity from the basic unit through the shared connector.
TS Adapter IE Basic (basic unit) and the TS module can be installed differently:
Installing on the S7-300 standard rail. This requires an optionally available standard sectional rail adapter
Installation on a standard rail
Wall mounting
Enclosure mounting
Product package
The following are supplied with the basic unit TS Adapter IE Basic:
DVD "SIMATIC TeleService Edition" with software and documentation
Support collar for Ethernet plug
TS Adapter IE Advanced
The TS Adapter IE Advanced makes it possible to access via the Internet all plant automation components, such as S7-CPUs, which are connected to Industrial Ethernet. To facilitate this a TIA Portal Version V12 SP1 or higher is required which runs on a programming device/PC under Windows 7 or Windows Server 2008.
TS Adapter IE Advanced connection types:
Direct connection to programming device/PC: The TS Adapter IE Advanced can be parameterized with direct connection to the programming device/PC via Ethernet (LAN)
Connection to the GSM network (GPRS): For connection to the GSM network, the TS Adapter IE Advanced must be operated together with the TS module GSM
Connection to the Internet via DSL: For connection to the Internet, a DSL router must be operated at the WAN port of the TS Adapter IE Advanced
Connection to the company network: Connection to the company network takes place directly at the WAN port of the TS Adapter IE Advanced
The TS Adapter IE Advanced has the following technical features:
Standard S7-1200 housing, with 55 mm width
Direct connection to system network (Industrial Ethernet); 2 ports (LAN)
Connection to public grid; 1 port (WAN)
24 V DC connection
Plug-in TS modules
Types of installation
There are three alternative methods for mounting the TS Adapter IE Advanced:
On the standard rails of the S7-300 with mounting rail adapters that can be ordered separately
On a standard DIN rail
Wall mounting
Product package
TS Adapter IE Advanced
CD "TS Adapter IE Advanced" with documentation, open-source components and default certification