Especially designed for constructing real-time (RT) and isochronous real-time (IRT) Industrial Ethernet networks in line, star and ring topologies with 10/100 Mbit/s (integrated redundancy manager); construction of redundant ring connections possible
Combination of the switching mechanisms "Cut Through" and "Store and Forward" for optimized performance
Electrical or optical connection to stations or network in accordance with the port type of the devices
Robust metal enclosure for space-saving cabinet installation on a standard DIN rail, S7-300 profile rail or for wall mounting
Rugged, industry-standard station connections with PROFINET-compatible connectors that offer additional strain relief and bending strain relief thanks to latching on the housing
Redundant power supply
Can be used for high-availability applications and can be replaced during normal operation thanks to redundant transmission characteristics
Diagnostics on the device by means of LEDs (power, link status, data communication)
Error signaling contact with easy adjustment using the SET button
The devices feature PROFINET diagnostics, SNMP access, integral web server and automatic e-mail sending function for remote diagnostics and signaling over the network
Different device versions with copper and fiber-optic interfaces (BFOC, SC RJ)
Device variants with IP65/67 protection for cabinet-free plant concepts with PROFINET-compliant push pull connection systems
Note:
SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were adopted from the respective standard products. SIPLUS extreme specific information was added.
SIPLUS SCALANCE X202-2P IRT
Article No.
6AG1 202-2BH00-2BA3
Article No. based on
6GK5 202-2BH00-2BA3
Ambient temperature range
-25 ... +60 °C
Conformal coating
Coating of the printed circuit boards and the electronic components
Technical specifications
The technical data of the standard product applies except for the ambient conditions.
Ambient conditions
Relative humidity
100%, condensation/frost permitted. No commissioning in bedewed state.
Biologically active substances, compliance with EN 60721-3-3
Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!
Chemically active substances, compliance with EN 60721-3-3
Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must remain in place over the unused interfaces during operation!
Mechanically active substances, compliance with EN 60721-3-3
Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation!
Air pressure (depending on the highest positive temperature range specified)
1 080 ... 795 hPa (-1 000 ... +2 000 m) see ambient temperature range