Motor reactorsLine voltage 380 ... 480 V 3 AC | Motor reactor (for pulse frequencies of 2 kHz to 4 kHz) |
|---|
| 6SL3000-2BE32-1AA0 | 6SL3000-2BE32-6AA0 | 6SL3000-2BE33-2AA0 | 6SL3000-2BE33-8AA0 | 6SL3000-2BE35-0AA0 |
|---|
Rated current | A | 210 | 260 | 310 | 380 | 490 | Power loss | | | | | | | | kW | 0.436 | 0.454 | 0.422 | 0.477 | 0.448 | | kW | 0.486 | 0.5 | 0.47 | 0.5 | 0.5 | Load connection | | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M12 | PE connection | | M8 screw | M8 screw | M8 screw | M8 screw | M8 screw | Cable length, max. between motor reactor and motor 1) | | | | | | | | m | 300 | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | 450 | Degree of protection | | IP00 | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | | mm | 300 | 300 | 300 | 300 | 300 | | mm | 285 | 315 | 285 | 285 | 365 | | mm | 257 | 277 | 257 | 277 | 277 | Weight, approx. | kg | 60 | 66 | 62 | 73 | 100 | Approvals, according to | | cURus | cURus | cURus | cURus | cURus | Suitable for Power Module | 6SL3310-1GE32-1AA3 (110 kW) | 6SL3310-1GE32-6AA3 (132 kW) | 6SL3310-1GE33-1AA3 (160 kW) | 6SL3310-1GE33-8AA3 (200 kW) | 6SL3310-1GE35-0AA3 (250 kW) |
Line voltage 380 ... 480 V 3 AC | Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz) |
|---|
| 6SL3000-2AE36-1AA0 | 6SL3000-2AE38-4AA0 | 6SL3000-2AE41-0AA0 |
|---|
Rated current | A | 605 | 840 | 840 | 985 | Power loss | | | | | | | kW | 0.798 | 0.75 | 0.834 | 0.939 | | kW | 0.9 | 0.84 | 0.943 | 1.062 | Load connection | | 1 ? hole for M12 | 1 ? hole for M12 | 1 ? hole for M12 | 1 ? hole for M12 | PE connection | | M10 screw | M10 screw | M10 screw | M10 screw | Cable length, max. between motor reactor and motor 1) | | | | | | | m | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | Degree of protection | | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | mm | 410 | 410 | 410 | 410 | | mm | 392 | 392 | 392 | 392 | | mm | 292 | 292 | 292 | 302 | Weight, approx. | kg | 130 | 140 | 140 | 146 | Approvals, according to | | cURus | cURus | cURus | cURus | Suitable for Power Module | 6SL3310-1GE36-1AA3 (315 kW) | 6SL3310-1GE37-5AA3 (400 kW) | 6SL3310-1GE38-4AA3 (450 kW) | 6SL3310-1GE41-0AA3 (560 kW) |
Line voltage 500 ... 600 V 3 AC | Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz) |
|---|
| 6SL3000-2AH31-8AA0 | 6SL3000-2AH32-4AA0 | 6SL3000-2AH32-6AA0 | 6SL3000-2AH33-6AA0 | 6SL3000-2AH34-5AA0 |
|---|
Rated current | A | 175 | 215 | 260 | 330 | 410 | Power loss | | | | | | | | kW | 0.357 | 0.376 | 0.389 | 0.4 | 0.481 | | kW | 0.403 | 0.425 | 0.441 | 0.454 | 0.545 | Load connection | | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | PE connection | | M8 screw | M8 screw | M8 screw | M8 screw | M8 screw | Cable length, max. between motor reactor and motor 1) | | | | | | | | m | 300 | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | 450 | Degree of protection | | IP00 | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | | mm | 300 | 300 | 300 | 300 | 350 | | mm | 285 | 285 | 285 | 285 | 330 | | mm | 212 | 212 | 212 | 212 | 215 | Weight, approx. | kg | 34 | 34 | 40 | 43 | 56 | Approvals, according to | | cURus | cURus | cURus | cURus | cURus | Suitable for Power Module | 6SL3310-1GF31-8AA3 (110 kW) | 6SL3310-1GF32-2AA3 (132 kW) | 6SL3310-1GF32-6AA3 (160 kW) | 6SL3310-1GF33-3AA3 (200 kW) | 6SL3310-1GF34-1AA3 (250 kW) |
Line voltage 500 ... 600 V 3 AC | Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz) |
|---|
| 6SL3000-2AH34-7AA0 | 6SL3000-2AH35-8AA0 | 6SL3000-2AH38-1AA0 |
|---|
Rated current | A | 465 | 575 | 810 | 810 | Power loss | | | | | | | kW | 0.631 | 0.705 | 0.78 | 0.877 | | kW | 0.723 | 0.801 | 0.91 | 1.003 | Load connection | | 1 ? hole for M12 | 1 ? hole for M12 | 1 ? hole for M12 | 1 ? hole for M12 | PE connection | | M8 screw | M8 screw | M8 screw | M8 screw | Cable length, max. between motor reactor and motor 1) | | | | | | | m | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | Degree of protection | | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | mm | 410 | 410 | 410 | 410 | | mm | 392 | 392 | 392 | 392 | | mm | 292 | 292 | 279 | 279 | Weight, approx. | kg | 80 | 80 | 146 | 146 | Approvals, according to | | cURus | cURus | cURus | cURus | Suitable for Power Module | 6SL3310-1GF34-7AA3 (315 kW) | 6SL3310-1GF35-8AA3 (400 kW) | 6SL3310-1GF37-4AA3 (500 kW) | 6SL3310-1GF38-1AA3 (560 kW) |
Line voltage 660 ... 690 V 3 AC | Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz) |
|---|
| 6SL3000-2AH31-0AA0 | 6SL3000-2AH31-5AA0 | 6SL3000-2AH31-8AA0 | 6SL3000-2AH32-4AA0 | 6SL3000-2AH32-6AA0 |
|---|
Rated current | A | 100 | 100 | 150 | 150 | 175 | 215 | 260 | Power loss | | | | | | | | | | kW | 0.215 | 0.269 | 0.237 | 0.296 | 0.357 | 0.376 | 0.389 | | kW | 0.26 | 0.3 | 0.26 | 0.332 | 0.403 | 0.425 | 0.441 | Load connection | | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | PE connection | | M8 screw | M8 screw | M8 screw | M8 screw | M8 screw | M8 screw | M8 screw | Cable length, max. between motor reactor and motor 1) | | | | | | | | | | m | 300 | 300 | 300 | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | 450 | 450 | 450 | Degree of protection | | IP00 | IP00 | IP00 | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | | | | mm | 270 | 270 | 270 | 270 | 300 | 300 | 300 | | mm | 248 | 248 | 248 | 248 | 285 | 285 | 285 | | mm | 200 | 200 | 200 | 200 | 212 | 212 | 212 | Weight, approx. | kg | 26 | 26 | 26 | 26 | 33 | 35 | 40 | Approvals, according to | | – | – | – | – | – | – | – | Suitable for Power Module | 6SL3310-1GH28-5AA3 (75 kW) | 6SL3310-1GH31-0AA3 (90 kW) | 6SL3310-1GH31-2AA3 (110 kW) | 6SL3310-1GH31-5AA3 (132 kW) | 6SL3310-1GH31-8AA3 (160 kW) | 6SL3310-1GH32-2AA3 (200 kW) | 6SL3310-1GH32-6AA3 (250 kW) |
Line voltage 660 ... 690 V 3 AC | Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz) |
|---|
| 6SL3000-2AH33-6AA0 | 6SL3000-2AH34-5AA0 | 6SL3000-2AH34-7AA0 | 6SL3000-2AH35-8AA0 | 6SL3000-2AH38-1AA0 |
|---|
Rated current | A | 330 | 410 | 465 | 575 | 810 | 810 | Power loss | | | | | | | | | kW | 0.4 | 0.481 | 0.631 | 0.705 | 0.78 | 0.877 | | kW | 0.454 | 0.545 | 0.723 | 0.801 | 0.91 | 1.003 | Load connection | | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M12 | 1 ? hole for M12 | 1 ? hole for M12 | 1 ? hole for M12 | PE connection | | M8 screw | M8 screw | M8 screw | M8 screw | M8 screw | M8 screw | Cable length, max. between motor reactor and motor 1) | | | | | | | | | m | 300 | 300 | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | 450 | 450 | Degree of protection | | IP00 | IP00 | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | | | mm | 300 | 350 | 410 | 410 | 410 | 410 | | mm | 285 | 330 | 392 | 392 | 392 | 392 | | mm | 212 | 215 | 292 | 292 | 279 | 279 | Weight, approx. | kg | 43 | 56 | 80 | 80 | 146 | 146 | Approvals, according to | | – | – | – | – | – | – | Suitable for Power Module | 6SL3310-1GH33-3AA3 (315 kW) | 6SL3310-1GH34-1AA3 (400 kW) | 6SL3310-1GH34-7AA3 (450 kW) | 6SL3310-1GH35-8AA3 (560 kW) | 6SL3310-1GH37-4AA3 (710 kW) | 6SL3310-1GH38-1AA3 (800 kW) |
1) Longer cable lengths for specific configurations are available on request.
|
|