The compact installation unit comprises a base plate and a top plate, a self-aligning bolt and two countersunk screws. The top plate is aligned and fixed above the base plate with the two countersunk screws. This results in a stable unit. The height of the top plate is adjusted so that it is three millimeters above the installation height with load cell. In this state the compact installation unit serves as an installation aid and can be used as a dummy for light installation jobs. Prior to installation, the load cell is inserted with the self-aligning bolt into the compact installation unit. Then the complete unit is installed in the scales. As the result, the load bearing implement and the installation units are aligned. The load cells are not yet loaded. Finally the load bearing implement is lowered by undoing two hex nuts under the top plate. The weight now rests on the load cells. In this state the load cell and the pressure pieces together form a self-centering unit. The compact installation unit permits sideways displacement of the top plate, and hence of the load bearing implement, by up to three millimeters. |