Possible applications | Container weighers |
Model | Compression load cell |
Rated load/maximum load Emax. | 100 t |
Accuracy class according to OIML R60 | C3 |
Max. load cell verification intervals nLC | 3 000 |
Min. scale intervals Vmin | |
| Emax/9 000 |
Minimum application range Rmin(LC) | 33% |
Combined error Fcomb | ± 0.02% Cn |
Repeatability Fv | ± 0.02% Cn |
Creep error Fcr | |
| ± 0.023% Cn |
Temperature effect | |
| 0.023% Cn/5 K |
| 0.017% Cn/5 K |
Min. dead load Emin | 0 kg |
Safe load limit Lu | 150% Emax |
Ultimate load LD | 300% Emax |
Safe side load LIq | 10% Emax |
Rated measuring path hn at Emax | 0.36 mm |
Recommended supply voltage (range) | 5 … 12 V DC |
Rated characteristic value Cn | 2.0 ± 0.02 mV/V |
Tolerance D0 of zero signal | ? ± 1.0% Cn |
Input resistance Re | 700 ? ± 7 ? |
Output resistance Ra | 700 ? ± 7 ? |
Insulation resistance Ris | 5 000 M? at 50 V DC |
Rated temperature range Btn | -10 … +40 °C (14 ... 104 °F) |
Operating temperature range Btu | -35 … +65 °C (-31 ... 149 °F) |
Storage temperature range Bts | -35 … +65 °C (-31 ... 149 °F) |
Sensor material | Stainless steel |
Degree of protection according to EN 60529; IEC 60529 | IP68 |
Cable connection | |
Function | Color |
| green |
| black |
- SIG + (measured signal +)
| white |
- SIG – (measured signal -)
| red |
| yellow |
| blue |
| transparent |