Operating PrincipleSITRANS F X vortex flowmeters measure flow rate by detecting the frequency at which alternating vortices are shed from a bluff body inserted into the flow stream. This principle of measurement is derived from the Karman phenomenon of vortex shedding. The frequency of the alternating vortices is proportional to the flow rate. 1 = Bluff Body, 2 = Pick-up The flowmeter calculates the flow velocity using the following equation: Q = A · V = A · d / St · f = 101.93 · f / K [m3/h] Where: Q = flow rate [m3/h] f = vortex shedding frequency [Hz] K = calibration constant [pulses/m3] d = width of the bluff body [m] St = Strouhal Number A = cross-section area [m2] V = flow velocity [m/s] RequirementsIn order to generate the vortex streets, the medium must have a minimum velocity:
|