Supply voltage | | | | | |
Load voltage L+ | | | | | |
| 24 V; From power module | 24 V; From power module | 24 V | 24 V; From power module | 24 V; From power module |
| Yes | Yes | Yes | Yes | Yes |
Input current | | | | | |
from load voltage L+ (without load), max. | 125 mA | 30 mA | 48 mA | 30 mA | 30 mA |
from backplane bus 3.3 V DC, max. | 10 mA | 10 mA | 10 mA | 10 mA | 10 mA |
Output voltage | | | | | |
Power supply to the transmitters | | | | | |
| Yes | Yes | Yes | | |
| Yes; approx. 200 mA for module | Yes | Yes | | |
Power loss | | | | | |
Power loss, typ. | 0.6 W | 0.6 W | 1.2 W | 0.6 W | 0.6 W |
Address area | | | | | |
Address space per module | | | | | |
| 8 byte | 8 byte | 4 byte | 4 byte | 4 byte |
Analog inputs | | | | | |
Number of analog inputs | 4 | 4; 2 for 3 or 4-wire connection | 2 | 2 | 2 |
permissible input voltage for voltage input (destruction limit), max. | | 9 V | | 20 V; +/-20 V, continuous | 9 V |
permissible input current for current input (destruction limit), max. | 30 mA; limited electronically | | 50 mA | | |
Constant measurement current for resistance-type transmitter, typ. | | 1.67 mA | | | 1.25 mA |
Cycle time (all channels) max. | 40 ms; 33 to 40 ms | Number of active channels per module x basic conversion time | 0.5 ms; 0.5 ms for 2 channels without noise suppression, 18 / 21 ms per channel with noise suppression | Number of active channels per module x basic conversion time | Number of active channels per module x basic conversion time |
Technical unit for temperature measurement adjustable | | No | | Yes; Celsius / Fahrenheit | Yes |
Input ranges | | | | | |
| No | No | No | Yes | Yes |
| Yes | No | Yes | No | No |
| No | No | No | Yes | Yes |
| No | Yes | No | No | Yes |
| No | Yes | No | No | Yes |
Input ranges (rated values), voltages | | | | | |
| | | | Yes | |
| | | | 1 M? | |
Input ranges (rated values), currents | | | | | |
| | | Yes | | |
| Yes; Into 25 Ohm | | Yes | | |
Input ranges (rated values), thermocouples | | | | | |
| | | | Yes | |
| | | | 1 M? | |
| | | | Yes | |
| | | | 1 M? | |
| | | | Yes | |
| | | | 1 M? | |
| | | | Yes | |
| | | | 1 M? | |
| | | | Yes | |
| | | | 1 M? | |
| | | | Yes | |
| | | | 1 M? | |
| | | | Yes | |
| | | | 1 M? | |
| | | | Yes | |
| | | | 1 M? | |
| | | | Yes | |
| | | | 1 M? | |
| | | | Yes | |
| | | | 1 M? | |
Input ranges (rated values), resistance thermometer | | | | | |
| | | | | Yes |
| | | | | 10 M? |
| | Yes; Standard/climate | | | Yes |
| | 2 000 k? | | | 10 M? |
| | | | | Yes |
| | | | | 10 M? |
| | | | | Yes |
| | | | | 10 M? |
| | | | | Yes |
| | | | | 10 M? |
| | | | | Yes |
| | | | | 10 M? |
| | Yes; Standard/climate | | | Yes |
| | 2 000 k? | | | 10 M? |
| | | | | Yes |
| | | | | 10 M? |
| | | | | Yes |
| | | | | 10 M? |
| | | | | Yes |
| | | | | 10 M? |
Input ranges (rated values), resistors | | | | | |
| | Yes | | | Yes |
| | 2 000 k? | | | 10 M? |
| | Yes | | | Yes |
| | 2 000 k? | | | 10 M? |
| | Yes | | | Yes |
| | 2 000 k? | | | 10 M? |
| | | | | Yes |
| | | | | 10 M? |
Thermocouple (TC) | | | | | |
Temperature compensation | | | | | |
| | | | Yes; possible with TM-E15S24-AT, TM-E15C24-AT | Yes |
| | | | Yes; one external compensating box per channel | |
Characteristic linearization | | | | | |
| | Yes; for Pt100, Ni100 | | Yes | Yes; for Ptxxx, Nixxx |
| | | | Type B, C, E, J, K, L, N, R, S, T to IEC 584 | |
| | Pt100 (standard, climatic range), Ni100 (standard, climatic range) | | | Ptxxx, Nixxx |
Cable length | | | | | |
| 200 m | 200 m | 200 m | 50 m | 200 m |
Analog value generation for the inputs | | | | | |
Measurement principle | integrating | integrating | Sigma Delta | integrating | integrating (Sigma-Delta) |
Integration and conversion time/resolution per channel | | | | | |
| 13 bit; 4 to 20 mA: 13 bits | 16 bit; 150 ohms: 14 bits; 300, 600 ohms: 15 bits, Pt100, Ni100: 16 bits | 16 bit | 16 bit | 16 bit; for Pt100, Ni100, Ni120, Pt200, Ni200, Pt 500, Ni 500, Pt1000, Ni1000, Cu10: 15 bits + sign; for 150, 300, 600, 3000 ohms: 15 bits; for PTC: 1 bits |
| Yes | Yes | Yes | | |
| 16,67 / 20 ms | 16,7 / 20 ms | | 16,7 / 20 ms | 16,7 / 20 ms |
| 50 / 60 Hz | 50 / 60 Hz | 60 / 50 Hz / no | 50 / 60 Hz | 50 / 60 Hz |
| | 66 / 80 ms; additional conversion time for diagnostic wire break test | 0.04 ms; Without noise suppression 17/20 ms per channel with error | 66 ms; 66 / 80 ms; additional conversion time for diagnostic wire break test | Basic conversion time incl. integration time: 50 / 60 ms; additional conversion time for diagnostics of wire break test: 5 / 5 ms; additional conversion time for line compensation with 3-wire connection: 50 / 60 ms |
Smoothing of measured values | | | | | |
| Yes; in 4 stages | Yes; In four stages by means of digital filtering | Yes; In 4 stages: 1 x, 4 x, 16 x, 32 x cycle time | Yes; In four stages by means of digital filtering | Yes; In four stages by means of digital filtering |
| Yes; 1 x cycle time | Yes; 1 x cycle time | Yes; 1x | Yes; 1 x cycle time | Yes; 1 x cycle time |
| Yes; 4 x cycle time | Yes; 4 x cycle time | Yes; 4x | Yes; 4 x cycle time | Yes; 4 x cycle time |
| Yes; 16 x cycle time | Yes; 32 x cycle time | Yes; 16x | Yes; 32 x cycle time | Yes; 32 x cycle time |
| Yes; 32 x cycle time | Yes; 64 x cycle time | Yes; 32x | Yes; 64 x cycle time | Yes; 64 x cycle time |
Encoder | | | | | |
Connection of signal encoders | | | | | |
| | | | | |
| 750 ? | | 750 ? | | |
| | Yes | | | Yes |
| | Yes | | | Yes; internal compensation of the line resistances |
| | Yes | | | Yes |
Errors/accuracies | | | | | |
Linearity error (relative to input range), (+/-) | 0.01 % | 0.01 % | 0.03 % | 0.01 % | 0.01 % |
Temperature error (relative to input range), (+/-) | 0.003 %/K | 0.005 %/K | 0.03 %/K | 0.005 %/K | 0.0009 %/K |
Crosstalk between the inputs, min. | -50 dB | -50 dB | -100 dB | -50 dB | -50 dB |
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.05 % | 0.05 % | 0.01 % | 0.05 % | 0.05 % |
Operational error limit in overall temperature range | | | | | |
| | | | 0.1 %; +/-1.5 K for thermocouples, +/-7 K for thermocouples type C,+/-2.5 K with static thermal state (ambient temperature change < 0.3 K/min) | |
| 0.5 % | | 0.1 %; 0.2% without interference frequency suppression | | |
| | 0.6 % | | | Resistance-type transmitter: +/-0.1%; Pt100, Pt200, Pt500, Pt1000 standard: +/-1.0 K; Pt100, Pt200, Pt500, Pt1000 climate: +/-0.25 K; Ni100, Ni120, Ni200, Ni500, Ni1000 standard and climate: +/-0.4 K; Cu10 +/-1.5 K |
Basic error limit (operational limit at 25 °C) | | | | | |
| | | | 0.05 %; +/-1 K with thermocouples, +/-5 K with thermocouples type C, +/-1.5 K with static thermal state (ambient temperature change < 0.3 K/min) | |
| 0.3 % | | 0.05 %; 0.1% without interference frequency suppression | | |
| | 0.4 % | | | Resistance-type transmitter: +/-0.05%; Pt100, Pt200, Pt500, Pt1000 standard: +/-0.6 K; Pt100, Pt200, Pt500, Pt1000 climate: +/-0.13 K; Ni100, Ni120, Ni200, Ni500, Ni1000 standard and climate: +/-0.2 K; Cu10 +/-1 K |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | | | | | |
| 70 dB | 70 dB | 90 dB | 70 dB | 70 dB |
| | 90 dB | 100 dB | 90 dB | 90 dB |
Isochronous mode | | | | | |
Isochronous operation (application synchronized up to terminal) | No | No | Yes | | No |
Interrupts/diagnostics/status information | | | | | |
Alarms | | | | | |
| | | Yes | | |
Diagnostic messages | | | | | |
| Yes; Measuring range 1 to 5 V only | Yes | Yes; Measuring range 4 to 20 mA only | Yes; only thermocouples | Yes |
| Yes | Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes | Yes |
Diagnostics indication LED | | | | | |
| Yes | Yes | Yes | Yes | Yes |
Parameter | | | | | |
Remark | 7 byte | | 12 bytes, 4 bytes in compatibility mode | 4 byte | 7 byte |
Diagnostics wire break | 1 | Disable / enable | Disable / enable | Disable / enable (wire break is detected only in thermocouples) | Disable / enable |
Measurement type/range | 1 | deactivated/150 ohms/; 300 ohms/600 ohms/ Pt100 climatic/ Pt100 standard; Ni100 standard / Ni100 climatic, 2, 3 or 4-wire | deactivated / +/-20 mA / 4 to 20 mA | Deactivated/ +/- 80 mV/ TC-EL Type T (Cu-CuNi)/ TC-EL Type K (NiCr-Ni)/ TC-EL Type B (PtRh-PtRh)/ TC-EL Type c (Wer-Wer) TC-EL Type N (NiCrSi-NiSi)/ TC-EL Type E (NiCr-CuNi)/ TC-EL Type R (PtRh-Pt)/ TC-EL Type S (PtRh-Pt)/ TC-EL Type J (Fe-Cu-Ni)/ TC | Deactivated/ 150 Ohm / 300 Ohm / 600 Ohm /Pt100/Pt200/Pt500/Pt1000 each standard or climate range / Ni100/Ni120/Ni200/Ni500/Ni1000 each standard or climate range / Cu10 each standard or climate range / PTC |
Group diagnostics | 1 | Disable / enable | Disable / enable | Disable / enable | Disable / enable |
Overflow/underflow | 1 | Disable / enable | Disable / enable | Disable / enable | Disable / enable |
Comparison point | | | | none / yes, internal | |
Potential separation | | | | | |
Potential separation analog inputs | | | | | |
| No | No | No; however, increased permissible potential difference between the inputs. | No | No |
| Yes | Yes | Yes | Yes | Yes |
| No | Yes | Yes | Yes | Yes |
Permissible potential difference | | | | | |
Between the inputs and MANA (UCM) | | | | 140 V DC/100 V AC | |
between MANA and M internally (UISO) | | 75 V DC/60 V AC | | 75 V DC/60 V AC | 75 V DC/60 V AC |
Isolation | | | | | |
Isolation tested with | 500 V DC | 500 V DC | | 500 V DC | 500 V DC |
Standards, approvals, certificates | | | | | |
CE mark | Yes | Yes | Yes | Yes | Yes |
Ambient conditions | | | | | |
Ambient temperature during operation | | | | | |
| -25 °C; = Tmin | -25 °C; = Tmin | -25 °C; = Tmin | 0 °C; = Tmin | -25 °C; = Tmin |
| 70 °C; = Tmax | 70 °C; = Tmax | 70 °C; = Tmax | 70 °C; = Tmax | 60 °C; = Tmax |
Extended ambient conditions | | | | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | | | | | |
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) | 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) | 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) | 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) |
Resistance | | | | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation in corrosive atmospheres! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Dimensions | | | | | |
Width | 15 mm | 15 mm | 15 mm | 15 mm | 15 mm |
Height | 81 mm | 81 mm | 81 mm | 81 mm | 81 mm |
Depth | 52 mm | 52 mm | 52 mm | 52 mm | 52 mm |
Weights | | | | | |
Weight, approx. | 40 g | 40 g | 45 g | 40 g | 40 g |