Mode of operation | |
Measuring principle | FMCW radar level measurement |
Frequency | 24.2 ... 25.2 GHz FMCW |
Measuring range | 0.35 ... 100 m (1.15 ... 328.08 ft) |
Output | |
Analog output (HART) | |
| Optically isolated |
| Max. 600 ? |
| mA signal programmable as high, low or hold (LOE) |
Communication | HART, optional PROFIBUS PA |
Digital output | Relay, NC or NO function, max. 50 V DC, max. 200 mA, rating 5 W |
PROFIBUS PA protocol | Layer 1 and 2, Class A, Profile 3.01 |
Performance (Reference conditions according to IEC 60770-1) | |
Non-linearity | Greater of 25 mm (1 inch) or 0.25 % of span (including hysteresis and non-repeatability), over the full ambient temperature range |
Non-repeatability | ? 10 mm (0.4 inch) |
Rated operating conditions | |
Amb. temperature for enclosure | -40 ... +65 °C (-40 ... +149 °F) |
Location | Indoor/outdoor |
Installation category | II |
Pollution degree | 4 |
Medium conditions | |
Dielectric constant | ?r > 1.4 |
Process temperature range | -40 ... +200 °C (-40 ... +392 °F) |
Vessel pressure | 0.5 bar g (7.25 psi g) maximum |
Design | |
Weight | Approx. 6.1 kg (13.4 lb) with 3 inch universal flange |
Materials | |
| Die-cast aluminum, painted |
| IP67/Type 4X/NEMA 4X/Type 6/NEMA 6 |
| 2 x M20 x 1.5 or ?" NPT |
Process connections | |
- Universal flanges, 304 stainless steel, flat faced, with integral Easy Aimer
| 3 inch/80 mm, 4 inch/100 mm, 6 inch/150 mm (mates with flange EN 1092-1, ASME B16.5, or JIS B2238 bolt pattern), 0.5 bar g (7.25 psi g) max. pressure |
Programming | |
Intrinsically Safe Siemens handheld programmer (ordered separately) | Infrared receiver |
- Approvals for handheld programmer
| IS model: ATEX II 1G EEx ia IIC T4, CSA/FM Class I, Div. 1, Groups A, B, C, D T6 at max. ambient temperature of 40 °C (104 °F) |
Handheld communicator | HART Communicator 375 |
PC | SIMATIC PDM |
Display (local) | Alphanumeric LCD for readout and entry |
Power supply | 100 ... 230 V AC ± 15 % (50/60 Hz), 6 W (12 VA) or 24 V DC +25/-20 %, 6 W (optional) |
Certificates and approvals | |
General | CSAUS/C, CE, FM, RCM |
Radio | European Radio (R&TTE), Industry Canada, FCC, RCM |
Hazardous Areas | CSA/FM Class II, Div. 1, Groups E, F, and G, Class III ATEX II 1D, 1/2 D, 2D T85 °C INMETRO ExtD A20 IP67 T85 °C EAC Ex DIP A20 Ta 85 °C IP67 |
Optional equipment | |
Dust cap | PTFE |
Air purge connection | 1/8" NPT |