Expanded I/Os (additional 4 ... 20 mA outputs) with form c relays
UniMass (requires RTD)
Communications: HART, BACnet MSTP/BACnet IP, Modbus RTU & TCP/IP, Ethernet IP, Johnson N2 and VT100 RS 232
Accuracy
Accuracy
± 0.5 % ... 1.0 % of flow, for velocities greater than 0.3 m/s (1 ft/s) ± 0.0015 ... 0.003 m/s (± 0.005 ... 0.01 ft/s), for velocities less than 0.3 m/s (1 ft/s)
Batch repeatability
± 0.15 % of flow, for velocities greater than 0.3 m/s (1 ft/s) ± 0.0005 m/s (± 0.0015 ft/s), for velocities less than 0.3 m/s (1 ft/s)
Data refresh rate
5 Hz
Rated operation conditions
Degree of protection
IP65 (NEMA 4X)
Liquid temperature
Standard
-40 ... +120 °C (-40 ... +250 °F)
Optional
-40 ... +230 °C (-40 ... +450 °F)
Ambient temperature
-18 … +60 °C (0 … +140 °F)
Design
Dimensions
see SITRANS F US Clamp-on “System info and selection guide”
Weight
see diagrams
Power supply
90 ... 240 V AC, 50 ... 60 Hz, 30 VA or 9 ... 36 V DC, 12 W
Indication and operation
Data logger memory
1 MByte
Display
128 x 240 pixel LCD with backlight
Keypad
33 keypad buttons with tactile feedback
Language options
English, Spanish, German, Italian, French, selectable by software
Transmitter: Ex II (1) G [Ex ia] IIC Ex II 3 (1) G Ex nC [ia] IIC T5
Sensors: Ex II 1 G Ex ia IIC T5
IECEx
Pending
SITRANS FUS1010 IP66 (NEMA 7) wall mount explosionproof
Enclosure IP66 (NEMA 7)
Input
Flow range
± 12 m/s (± 40 ft/s), bidirectional
Flow sensitivity
0.0003 m/s (0.001 ft/s), flow rate independent
Pipe size
6.4 mm ... 9.14 m (0.25” ... 360”)
Optional inputs per channel
Current: 20 mA DC
Temperature: 2 x 4 wire 1 k? RTD
Output
Outputs single channel
Current: 20 mA DC (1 k? at 30 V DC)
Voltage: 10 V DC (5 k? min.)
Status Alarm: 4 x SPDT Relays
Pulse rate: 5 kHz
Communications; HART, BACnet MSTP/BACnet IP, Modbus RTU & TCP/IP, Ethernet IP, Johnson N2 and VT100 RS 232
Accuracy
Accuracy
± 0.5 % ... 1.0 % of flow, for velocities greater than 0.3 m/s (1 ft/s) ± 0.0015 ... 0.003 m/s (± 0.005 ... 0.01 ft/s), for velocities less than 0.3 m/s (1 ft/s)
Batch repeatability
± 0.15 % of flow, for velocities greater than 0.3 m/s (1 ft/s) ± 0.0005 m/s (± 0.0015 ft/s), for velocities less than 0.3 m/s (1 ft/s)
Data refresh rate
5 Hz
Rated operation conditions
Degree of protection
IP66 (NEMA 7)
Liquid temperature
Standard
-40 ... +120 °C (-40 ... +250 °F)
Optional
-40 ... +230 °C (-40 ... +450 °F)
Ambient temperature
-18 … +60 °C (0 … 140 °F)
Design
Dimensions
see SITRANS F US Clamp-on “System info and selsction guide”
Weight
see diagrams
Power supply
90 ... 240 V AC, 50 ... 60 Hz., 30 VA or 9 ... 36 V DC, 12 W
Indication and operation
Data logger memory
1 MByte
Display
128 x 240 pixel LCD with backlight
Keypad
33 keypad buttons with tactile feedback
Language options
English, Spanish, German, Italian, French
Certificates and approvals
FM and CSA ratings
Transmitter
XP Class I, Div 1 D-I Class II, Div 1 N-I Class I, Div 2 S Class II, Div 2