Mode of operation | |
Measuring principle | Pulse radar level measurement |
Frequency | 5.8 GHz (North America 6.3 GHz) |
Measuring range | 0.3 ... 20 m (1.0 ... 65 ft) |
Output | |
Analog output | 4 ... 20 mA |
Accuracy | ± 0.02 mA |
Span | Proportional or inversely proportional |
Communications | HART |
Performance (reference conditions) |
Accuracy | ± the greater of 0.1 % of range or 10 mm (0.4 inch) |
Influence of ambient temperature | 0.003 %/K |
Repeatability | ± 5 mm (2 inch) |
Fail-safe | mA signal programmable as high, low or hold (LOE) |
Rated operating conditions | |
Installation conditions | |
| Indoor/outdoor |
Ambient conditions (enclosure) | |
| -40 ... +80 °C (-40 ... +176 °F) |
| I |
| 4 |
Medium conditions | |
Dielectric constant ?r | ?r > 1.6 (for ?r < 3, use stillpipe) |
Vessel temperature | -40 ... +80 °C (-40 ... +176 °F) |
Vessel pressure | 3 bar g (43.5 psi g) |
Design | |
Enclosure | |
| PBT (Polybutylene Terephthalate) |
| PEI (Polyether Imide) |
| 2 x M20 x 1.5 or 2 x ?" NPT with adapter |
Degree of protection | Type 4X/NEMA 4X, Type 6/NEMA 6, IP67, IP68 |
Weight | 1.97 kg (4.35 lb) |
Antenna | |
| Polypropylene rod, hermetically sealed construction |
| Standard 100 mm (4 inch) shield for maximum 100 mm (4 inch) nozzle or optional 250 mm (10 inch) long shield |
Process connections | 1?" NPT [(Taper), ANSI/ASME B1.20.1] R 1?" [(BSPT), EN 10226] G 1?" [(BSPP), EN ISO 228-1] |
Power supply | - Nominal 24 V DC with max. 550 ?, maximum 30 V DC
- 4 ... 20 mA
|
Certificates and approvals | |
General | CSAUS/C, CE, FM, RCM |
Marine | - Lloyd's Register of Shipping
- ABS Type Approval
|
Radio | FCC, Industry Canada, and European (R&TTE), RCM |
Hazardous | |
- Intrinsically Safe (Brazil)
| INMETRO Ex ia IIC T4 Ga |
- Intrinsically Safe (Canada)
| CSA Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Group G; Class III |
- Intrinsically Safe (Europe)
| ATEX II 1G EEx ia IIC T4 |
- Intrinsically Safe (International)
| IECEx Ex ia IIC T4 |
- Intrinsically Safe (Russia/Kazakhstan)
| EAC Ex ia |
| FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III |
Programming | |
Handheld programmer | HART communicator 375 |
PC | SIMATIC PDM |
Intrinsically safe Siemens handheld programmer (optional) | Infrared receiver |
- Approvals (handheld programmer)
| ATEX II 1G EEx ia IIC T4 CSA and FM Class I, Div. 1, Groups A, B, C, D, T6 at max. ambient |
Display (local) | Multi-segment alphanumeric liquid crystal with bar graph (representing level) available in four languages |