Lead-in protectionThis is a purely mechanical protection of the busbar system for wall and ceiling lead-in. The lead-in protection can be retrofitted. BD2-400-D and BD2-1250-D: Bushing fuse for currents up to 400 A or from 630 to 1250 A End flangeAn end flange is provided to terminate the busbar line. 2 sizes are available Left: BD2-400-FE: End flanges for currents up to 400 A Right: BD2-1250-FE: End flanges for currents from 630 to 1250 A Optional equipment for IP54Upright installation You can increase the degree of protection to IP54 by adding an additional upper flange to the connection positions. Left: Connection points between trunking units with BD2-HF Right: Connection position trunking units/end flange with BD2-HFE Flat installation The IP54 higher degree of protection is achieved by fitting an additional upper flange at the connection points, at the end flange and at the tap-off points. Left: Connection points between trunking units with BD2-FF Right: Connection position trunking units/end flange with BD2-FFE Outgoing openings with BD2-FAS Vertical installation You can increase the degree of protection by adding additional flanges to all connection positions and all outgoing points (rear and front). Left: Connection points between straight trunking units with BD2-...-VF Right: Outgoing openings with BD2-FAS Optional equipment for IP55Trunking units The higher degree of protection IP55 is achieved by fitting additional seals and a flange at the connection points and at the outgoing points (not in conjunction with feeder units and flexible junction units suitable). Connection point between trunking units with BD2-...-FS Connection point between trunking unit and end flange with BD2-...-FSE Outgoing openings with BD2- ... -FAS, top and bottom Outgoing units You can increase the degree of protection to IP55 by adding additional seals to the outgoing unit. BD2-AK1-IP55 BD2-AK2X(3X)-IP55 BD2-AK02X(03X)-IP55 BD2-AK04(05, 06)-IP55 Optional equipment for mountingMounting bracket The universal mounting bracket can be used for all types of vertical and flat mounting. BD2-400-BB and DB2-1250-BB: Mounting brackets up to 400 A or from 630 to 1250 A Spacing bracket Spacing bracket to compensate for building tolerances between the busbar enclosure and the wall or ceiling. The spacing bracket is pushed onto the BD2-...-BB mounting bracket and screwed into place. Can also be used as interim mounting if BD2 lines are arranged vertically. BD2-BD: Spacing bracket Spacers Spacers to compensate for wall or ceiling distance between infeed enclosures and trunking units. The spacers are snapped onto the mounting bracket. BD2-DSB: Spacers Mounting elements for vertical lines These comprise a wall mounting element and optional equipment for ceiling mounting. To compensate for any unevenness in the wall, the mounting elements are adjustable. BD2-BWV: Wall mounting for busbar lines and final infeed The ceiling mounting must be used as a support element for transitions from horizontal to vertical lines. BD2-BDV: Ceiling mounting for busbar lines BD2-BVF: Wall mounting for busbar line at each terminal block BD2-BVC wall mounting element, at a distance of 1.6 m on the busbar line in conjunction with mounting rail |
| Каталог 2018 | Каталог 2017 | Каталог 2016 | Каталог 2015 | Каталог 2014 | Каталог 2013 | Каталог 2012 | Сертификат | Контакты | Карта сайта | Поиск |


