Acoustic and Motion Sensing Process Protection Selection Guide Criteria
SITRANS DA400
SITRANS AS100
Milltronics MFA 4p
Milltronics MSP-7
SITRANS WM100
Typical industries
Mining, water/wastewater, chemicals/petrochemicals and oil & gas industry
Aggregates, grain, cement, food processing, power generation, steel processing
Aggregates, cement, mining, wastewater, grain
General industrial applications
Aggregates, cement, mining
Typical Applications
Oscillating displacement pumps such as diaphragm piston pumps, piston pumps and hose-type diaphragm piston pumps. Monitoring of flowing materials in pipes, conveyors or channels.
Pipes, pneumatic conveyors, aerated gravity flow systems, burst filter bag detection
Tail pulleys, driven pulleys, motor shaft sensing, screw conveyor flights, bucket elevators
Tail pulley shafts, driven pulleys, motor shaft sensing, belt or drag conveyors, screw conveyor flights, bucket elevators, fans and pumps
Tail pulleys, driven pulleys, motor shaft sensing, screw conveyor flights, bucket elevators
Operation
Acoustic detection of cavitation, optionally acoustic detection of impact noises of high frequency
Acoustic sensing
Motion sensing
Motion sensing
Motion sensing
Enclosure
Electronics housing, Makrolon IP65, sensor, stainless steel material number W.-Nr. 1.4571 (316Ti SST)
Compact 304 or 303 stainless steel, IP68
Type 4X/NEMA 4X/IP65 polycarbonate
Type 4X/NEMA 4X/IP67 aluminum
Type 4X/NEMA 4X/IP67 aluminum
Sensor mounting
Screw to outside of pump housing. For material flow monitoring on the outside of pipes, channels, chutes or raceways
Sensor non-invasive: glue or weld-on disc, bolt or weld-on tab, drill and tap
Non-contacting probes secured with supplied flange
Non-contacting probe secured with supplied flange
Non-contacting, secured with supplied flange
Operating temperature
Electronics: -20 ... +60 °C (-4 ... +140 °F) Sensor: -20 ... +110 °C (-4 ... +230 °F)
-20 ... +80 ?C (-4 ... +176 ?F)1)
-20 ... +50 ?C (-4 ... +122 ?F)2)
-40 ... +60 °C
(-40 ... +140 °F)
-40 ... +60 ?C (-40 ... +140 ?F)
Power requirements
19 V ... 36 V DC, < 100 mA
20 ... 30 V DC, 18 mA
100/115/200/230 V AC ± 10 % 50/60Hz, 15 VA
21 ... 28 V DC, 40 mA max.
115 or 230 V AC ± 10 % 50/60 Hz, 7 VA
Approvals
CE, PROFIBUS DP, and PROFIBUS PA conform, Ex protection to ATEX 1G or 1D
CE, RCM, CSA/FM Class II, Div. 1, Group E, F, G optional, ATEX II, 2GD, 3D optional, EAC
CSAUS/C , CE, RCM
CE, RCM
CSAUS/C , CE, RCM
1) Extended temperature model -40 ... +125 °C (-40 ... +257 °F) available (CE version)
2) Probes available for -40 ... +260 °C (-40 ... +500 °F)