Input | |
Measuring range | 1.66 ... 3 300 pF |
Span | Min. 3.3 pF |
Output | |
Loop current | Continuous signal 4 ... 20 mA/20 ... 4 mA according to NAMUR 43 |
Accuracy (transmitter) | |
Temperature stability | 0.25 % of actual capacitance value |
Non-linearity and repeatability | < 0.4 % of full scale and actual measurement value |
Accuracy | Deviation < 0.5 % of actual measurement value |
Rated operating conditions1) | |
Ambient conditions | |
| -40 ... +85 °C (-40 ... +185 °F)2)3) |
| I |
| 4 |
| Type 4/NEMA 4/IP65 (optional IP68) |
Installation conditions | |
| Indoor/outdoor |
| -1 ... +35 bar g (-14.6 ... +511 psi g) |
| -40 ... +200 ?C (-40 ... +392 ?F)4) |
- Min. dielectric constant ?r
| 1.5 |
- Min. difference in dielectric constant for interface measurement
| 5 |
Design | |
Material | |
| Aluminum, epoxy-coated |
Probe diameter | |
| 19 mm (0.75 inch) with PFA jacket |
| 9 mm (0.35 inch) with PFA jacket, 6 mm (0.24 inch) without PFA jacket |
Active shield length | |
| Threaded: 120 mm (4.72 inch) Flanged: 100 mm (3.94 inch) |
| Threaded: 125 mm (4.92 inch) Flanged: 105 mm (4.13 inch) |
Process connection of probe | |
| ?",1",1?", 1?" NPT [(Taper), ANSI/ASME B1.20.1] R ?",1", 1?" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G ?",1", 1?" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] |
| 1?" NPT [(Taper), ANSI/ASME B1.20.1] R 1?" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G 1?" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] |
| 1 ... 4" ASME, DN 25 ... 100 |
Enclosure cable inlet | 2 x ?" NPT or 2 x M20 x 1.5 |
Power supply | 12 ... 30 V DC any polarity, 2-wire current loop circuit |
User Interface | |
Display | Local LCD, 4 digit, each 0 ... 9 and limited alpha characters |
Safety | |
Measurement current signaling | According to NAMUR NE 43, signal 3.8 ... 20.5 mA, fault ? 3.6 or ? 21 mA (22 mA) |
Certificates and approvals | |
General | CE, CSAUS/C, FM, RCM, KCC, EAC |
Dust Ignition Proof (Intrinsically Safe probe circuit) | |
| FM/CSA: Class II, Div. 1, Groups E, F, G Class III T4 |
| ATEX 1/2 D T100 °C |
Flame Proof (Intrinsically Safe probe circuit) | |
| ATEX II 1/2 G EEx d [ia] IIC T6 ... T1 ATEX II 1/2 D T100 °C |
| Ex d [ia Ga] IIC T6 … T4 Gb Ex tb IIIC T85 ?C … T100 °C Db IP65/IP68 |
| EAC Ex |
Explosion Proof (Intrinsically Safe probe circuit) | |
| Class I, Div. 1, Groups A, B, C, D Class II, Div. 1, Groups E, F, G Class III T4 |
Marine | Bureau Veritas Type Approval ABS Type Approval, Lloyds Register, BV |
Overfill Protection | AIB-Vincotte |
Other | Pattern Approval (AQSIQ, China), CRN, PED |