Mode of operation | |
Measuring principle | Vibrating point level switch |
Input | |
Measured variable | High, low, and demand |
Measuring frequency | |
| 125 Hz |
- Liquid/solid interface and short fork version
| 350 Hz |
Output | |
PNP | Open collector: Permanent load max. 0.4 A, short-circuit and overload protected Turn-on voltage: max. 50 V (reverse protection) |
2-wire without contact | Load current: - Min. 10 mA
- Max. 500 mA permanent
- Max. 2A < 200 ms
- Max. 5A < 50 ms
Voltage drop on the electronic module: max. 7 V with closed electric circuit Cut-off current with open electric circuit: max. 5 mA |
Relays | |
| SPDT relay |
| DPDT relay |
Relay delay | - From loss of vibration: approximately 1 second
- From resumption of vibration: approximately 1 ... 2 seconds
|
Signal delay | - Probe uncovered to covered: approximately 1 second
- Probe covered to uncovered: approximately 1 ... 2 seconds
|
Relay fail-safe | High or low, switch selectable |
Alarm output | - Relay 8 A at 250 V AC, non-inductive
- Relay 5 A at 30 V DC, non-inductive
|
mA output | 8/16 mA or 4 ... 20 mA |
| 4 ... 20 mA ± 0.1 mA |
Sensitivity | High or low, switch selectable |
Rated operating conditions | |
Installation conditions | |
| Indoor/outdoor |
Ambient conditions | |
| -40 ... +60 °C (-40 ... +140 °F) |
| III |
| 2 |
Medium conditions | |
| - All except CSA Class II, Group G:
-40 ... +150 °C (-40 ... +302 °F) - CSA Class II, Group G: -40 ... +140 °C (-40 ... +284 °F),
CSA temperature code T3B
|
- Max. threaded bushing temperature
| 60 °C (140 °F) |
- Max. enclosure surface temperature (Category 2D)
| 90 °C (194 °F) |
- Max. extension surface temperature (Category 1D)
| 150 °C (302 °F) |
| Max. 10 bar g (145 psi g) European Pressure Directive 2014/68/EU: Category 1 |
| - Standard version: approx. 20 g/l (1.2 lb/ft3)
- Liquid/solid interface version: approx. 50 g/l (3 lb/ft3)
- Optional low density version: approx. 5 g/l (0.3 lb/ft3)
|
Design | |
Material | |
| Epoxy coated aluminum |
Process connection | - Thread 1?" NPT [(Taper),
ANSI/ASME B1.20.1], R ?" [(BSPT), EN 10226], and flange options - Optional sliding bushing with 2" NPT [(Taper), ANSI/ASME B1.20.1] or BSP thread
- Thread material: stainless steel 303 (1.4301)
|
Tine material | Stainless steel 316L (1.4404), PTFE-coated tines are available upon special request |
Degree of protection | IP65/Type 4/NEMA 4 |
Conduit entry | 2 x M20 x 1.5 or 2 x ?" NPT |
Weight | - Standard version, no extensions: approx. 2.0 kg (4.4 lb)
- Solids/liquids version, no extensions: approx. 1.9 kg (4.2 lb)
|
Power supply | - 19 ... 230 V AC, +10 %, 50 ... 60 Hz, 8 VA
- 19 ... 55 V DC, +10 %, 1.5 W
|
Certificates and approvals | |
| - CSA/FM General Purpose
- CE
- CSA/FM Dust Ignition Proof
- RCM
- ATEX II 1/2 D
- CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E, F, G, FM Class I, Aex ia IIC, CSA Class I, Ex ia IIC, available only with power supply options 5 and 6
- ATEX II 1G and 1/2 G Eex ia IIC; ATEX II 1D and 1/2 D, available only with power supply option 5
|