| | | | | | Non-residential buildings | Residential buildings | Industry |
 | NEOZED fuse system | | MINIZED switch disconnectors, bases, fuse links from 2 A to 63 A of operational class gG, and accessories. In other words, a complete system. | Fuse system: IEC 60269-3; DIN VDE 0636-3; Safety switching devices: IEC/EN 60947-3 DIN VDE 0638; EN 60947-3 (VDE 0660-107) | ? | ? | ? |
| | DIAZED fuse system | | Fuse links from 2 A to 100 A in various operational classes, base versions with conventional screw base connections. A widely used fuse system. | IEC 60269-3; DIN VDE 0635; DIN VDE 0636-3; CEE 16 | ? | ? | ? |
Cylindrical fuse systems |
 | Cylindrical fuse links and cylindrical fuse holders | | Line protection or protection of switching devices. The fuse holders with touch protection ensure the safe “no-voltage” replacement of fuse links. Auxiliary switches can be retrofitted. | IEC 60269-1, -2, -3; NF C 60-200; NF C 63-210, -211; NBN C 63269-2, CEI 32-4, -12 Fuse holder: File no. E171267 | ? | ? | ? |
 | Fuse holders in size 10 x 38 mm and Class CC | | For the configuration of safety-related motor starter combinations. | IEC 60269-1,-2; IEC 60947-4; UL 4248-1 File No. E171267 CSA 250269, 6225-01 Auxiliary switches: UL 508, File No. E334003 | ? | -- | ? |
 | Class CC fuse systems | | Compliant with US standards with UL and CSA approval for exporting OEM customers and machine builders. A modern design with touch protection conforming to BGV A3 for use as "Branch Circuit Protection". | Fuse holders: UL 4248-1, E171267 CSA 22.2 Fuse links: UL 248-4, File no. E258218, CSA 231237, 1422-02 and 1422-82 | ? | ? | ? |
 | Busbar systems | | Busbars for NEOZED fuse bases, NEOZED fuse-disconnectors, MINIZED switch disconnectors, DIAZED fuse systems and for the cylindrical fuse system. Compact cylindrical fuse holder for busbars | EN 60439-1 (VDE 0660-500)
UL 4248-1, E337131 | ? | ? | ? |
LV HRC fuse system |
 | LV HRC fuse links | | Fuse links from 2 A to 1250 A for selective line protection and plant protection in non-residential buildings, in industry and in power supply companies. | IEC 60269-1, -2; EN 60269-1; DIN VDE 0636-2 CSA 16325 - 1422-02 | ? | ? | ? |
 | LV HRC signal indicators | | Signal indicators for blown fuses in all LV HRC fuse links with combination or front indicators with live grip lugs. And the extensive accessories required for the LV HRC fuses. | -- | ? | ? | ? |
 | LV HRC fuse bases and accessories | | Bases for screw or snap-on mounting onto DIN rail in 1-pole or 3-pole version. | IEC 60269-1, -2; EN 60269-1; DIN VDE 0636-2 UL 4248-1 File no. E141267-IZLT2 (only behind the branch circuit protection) CSA C22.2 No. 4248.1-07 | ? | ? | ? |
SITOR semiconductor fuses |
 | LV HRC design | | Fuse links of the LV HRC design in numerous versions for many applications ranging from 500 V to 1500 V and from 150 A to 1600 A. Fuses with slotted knife blade contacts, bolt-on lugs or female threads, special designs. | UL 4248-13, File no. E167357-JFHR2 | -- | -- | ? |
 | Design: cylinder fuses | | Fuse links, fuse holders – can be used as fuse switch disconnectors and fuse bases up to 600/690 V AC and 400/700 V DC from 1 A to 100 A in sizes 10 ? 38 mm, 14 ? 51 mm and 22 ? 58 mm. | Fuse links: UL 4248-13, File no. E167357-JFHR2 CSA 248170, 6225-01 | -- | -- | ? |
  | NEOZED, DIAZED design | | NEOZED fuse links for 400 V AC and 250 V DC and DIAZED for 500 V AC and 500 V DC. | -- | -- | -- | ? |
Photovoltaic fuses |
 | PV cylindrical fuses | | Fuses with a rated voltage of 1000 V DC and operating class gPV for protecting photovoltaic modules, their connecting cables and other components. | IEC 60269-6 | ? | ? | ? |
 | PV summation fuses | | Fuses with a rated voltage of 1000 V and 1500 V DC, a rated current from 63 A to 630 A and operating class gPV for protecting connecting cables and other components. | IEC60269-6 | ? | ? | ? |