Mode of operation |
Measuring principle | Ultrasonic level switch |
Measuring range | |
Measuring range in liquids | 0.25 ... 5 m (0.8 ... 16.4 ft) |
Measuring range in bulk solids | 0.25 ... 3 m (0.8 ... 9.8 ft) |
Output | |
AC Version (relay) | 2 SPDT Form C contacts, rated 5 A at 250 V AC or 30 V DC, resistive load; rated 1 A at 48 V DC resistive load |
DC Version (relay) | 2 SPDT Form C contacts, rated 5 A at 30 V DC, resistive load; rated 1 A at 48 V DC resistive load |
DC Version (transistor) | 2 switches, rated max. 100 mA, 48 V DC |
Accuracy | |
AC/DC version | |
| 3 mm (0.1 inch) |
| 0.25 % of measuring range |
Rated operation conditions | |
Installation conditions | |
| Indoors/outdoors |
| 12° |
Ambient conditions | |
| -40 ... +60 °C (-40 ... +140 °F) |
- If mounted in metal threads
| -20 ... +60 °C (-5 ... +140 °F) |
Medium conditions | |
| 0.5 bar (7.25 psi) max. |
Design | |
Material | Polycarbonate with gasket |
Weight | Approx. 1.5 kg (3.3 lb) |
Transducer material | PVDF or ETFE copolymer |
Threaded mounting | 2" NPT [(Taper), ANSI/ASME B1.20.1] R 2" [(BSPT), EN 10226] or G 2" [(BSPP), EN ISO 228-1] |
| For 3" ASME, DN 65, PN 10, and JIS 10 K3B |
Sanitary mounting | 4" sanitary fitting clamp |
Power supply | |
AC version | 100 ... 230 V AC, ± 15 %, 50/60 Hz, max. 12 VA, 5 W |
DC version | 18 ... 30 V DC, 3 W |
Displays and controls | |
Display | LCD, three digits, 9 mm (0.35 inch) high, for display of distance between sensor face and material, multi-segment graphic for operating state |
Memory | EEPROM, non-volatile |
Programming | 2 keys |
Electronics/enclosure | Connection: terminal block, max. 2.5 mm2 (14 AWG) solid/1.5 mm2 (16 AWG) stranded |
Degree of protection | IP67/Type 6/NEMA 6 |
Cable inlet | 2 x ?" NPT or 2 x PG 13.5 |
Certificates and approvals | CE, CSA US/C, FM |