Standards | IEC 60947-5-1, EN 60947-5-1 (VDE 0660 Part 200), IEC 60947-5-5, EN 60947-5-5 (VDE 0660 Part 210) |
Rated insulation voltageUi | 250 V |
Continuous thermal currentIth | 10 A |
Rated operational currentsIe at rated operational voltage Ue | |
- Alternating current AC-12
| |
| 10 A |
- Alternating current AC-15
| |
| 4 A |
| 4 A |
| 4 A |
| 4 A |
| |
| 6 A |
| 5 A |
| 2.5 A |
| 1 A |
| |
| 3 A |
| 1.5 A |
| 0.7 A |
| 0.3 A |
Contact stability | |
Test voltage/test current | 5 V / 1 mA |
Short-circuit protection (weld-free according to IEC 60947-5-1) | |
- DIAZED fuse links, utilization category gG
| 10 A TDz, 16 A Dz |
- Miniature circuit breaker with C characteristic according to IEC 60898 (VDE 0641)
| 10 A |
Mechanical endurance | |
- Pushbuttons and contact blocks
| 10 ? 106 operating cycles |
- Actuators, rotary or latching
| 3 ? 105 operating cycles |
| 3 ? 106 operating cycles |
Electrical endurance | |
- For utilization category AC-15 with 3RT10 15 to 3RT10 26 contactors
| 10 ? 106 operating cycles |
Climatic withstand capability | Climate-proof; suitable for marine applications |
Ambient temperature | |
- During operation, non-illuminated devices and complete with LED
| –25 ... +70 °C |
- During operation, devices with incandescent lamp
| –25 ... +60 °C |
- During storage, transport
| –40 ... +80 °C |
Degree of protection according to IEC 60529 (VDE 0470 Part 1) | |
- Connection of contact blocks and lampholders behind the front panel
| IP00 |
- Contact chambers of the contact blocks behind the front panel
| IP40 |
| IP65 |
- Actuators and indicators with protective cap
| IP67 |
Lamps | |
| Wedge base W2 ? 4.6 d |
| 6, 12, 24, 30, 48, 60 V; max. 1 W |
Connection | |
Plug-in connection with flat connectors for plug-in sleeves according to IEC 60760 | Flat connector 2 x 2.8/0.8 mm |
Protective measures | |
- For mounting in metal front plates and enclosures
| The actuators and lens assemblies must not be included in the protective measures. |
- For fitting into enclosures with total insulation
| The protective measure "Total insulation" is retained. |
Finger-safe according to EN 50274 and VBG 4 | With voltages > 50 V AC or 120 V DC, insulating sleeves must be fitted to the unassigned tab connections. |
Shock resistance according to IEC 60068-2-27 | |
Shock amplitude | ? 50 g |
Shock duration | 11 ms |
Shock form | Half-sine |