Converters ? = 125 A rated armature current: Permissible ambient air temperature during operation | Self-ventilated 0 °C to 45 °C |
Converters ? = 210 A rated armature current: permissible ambient temperature during operation | Enhanced air cooling with installed fan 0 °C to 40 °C |
Permissible ambient temperature during storage and transport | -25 °C to +70 °C |
Installation altitude | ? 1000 m above sea level (100 % load rating) > 1000 m to 5000 m above sea level |
Control stability | ?n = 0.006 % of the rated motor speed, valid for pulse encoder operation and digital setpoint |
| | ?n = 0.1 % of the rated motor speed valid for analog tacho and analog setpoint 2) |
Humidity class | Relative air humidity ? = 95 %, dewing not permissible 1) |
Climate class | Class 3K3 acc. to DIN IEC 60 721-3-3 |
Insulation | Pollution severity 2 acc. to DIN VDE 0110-1 (HD 625.1 S: 1996) dewing not permissible |
Overvoltage category | Category III acc. to DIN VDE 0110-1 for power section and power supply Category II acc. to DIN VDE 0110-1 for electronics |
Overvoltage resistance | Class 1 acc. to DIN VDE 0160 |
Degree of protection | IP00 acc. to EN 60 529 |
Safety class | Class I acc. to DIN VDE 0106, part 1 |
Shock hazard protection | Acc. to DIN VDE 0106 part 100 (VBG4) and DIN VDE 0113 part 5 |
RI suppression | No RI suppression acc. to EN 61 800-3 |
MTBF | > 200,000 h acc. to SN 29500 |
Mechanical rigidity | Acc. to DIN IEC 60 068-2-6 |
For stationary use constant amplitude: | |
| 0.075 mm in frequency range 10 Hz to 58 Hz |
| 9.8 ms -2 (1 x g) in frequency range > 9 Hz to 500 Hz |
For transport constant amplitude | |
| 3.5 mm in frequency range 5 Hz to 9 Hz |
| 9.8 ms -2(1 x g) in frequency range > 9 Hz to 500 Hz |
Approvals | |
UL/cUL 3) | UL-File-Nr.: E203250 |
Applicable standards | |
DIN VDE 0106 part 100 | Arrangement of operator control elements in the vicinity of components/parts at hazardous voltage levels. |
DIN VDE 0110 part 1 | Insulation coordination for electrical equipment in low-voltage installations |
EN 60 146-1-1 / DIN VDE 0558T11 | Semiconductor converters General requirements and line commutated converters |
EN 50178 / DIN VDE 0160 | Regulations for the equipment of electrical power installatons with electronic equipment. |
EN 61800-3 | Variable speed drives Part 3, EMC product standard including special test procedures |
EN 60068-2-6 acc. to degree of severity 12 (SN29010 part 1) | Mechanical stress |