Modular PID ControlParameterization software | Modular PID Control | Type of license | Single license | Software class | A | Current version | V 5.1 | Target system | SIMATIC S7-300 (CPU 313 or higher) SIMATIC S7-400 SIMATIC C7 | Required software packages | STEP 7 V5.3 SP2 or higher | Main memory configuration in PG/PC | 16 MB | Disk space required in PG/PC | 1.85 MB | Processor, at least | 486 | Windows swap area, approx. | 20 MB (max. possible) |
Standard function blocks | A_DEAD_B | CRP_IN | CPR_OUT |
|---|
Storage space requirements | Load memory | Work memory | Load memory | Work memory | Load memory | Work memory | | 898 bytes | 692 bytes | 182 bytes | 70 bytes | 206 bytes | 96 bytes | | 186 bytes | 44 bytes | 122 bytes | 20 bytes | 114 bytes | 14 bytes | Runtimes in S7-300 | 0.13 to 0.17 ms | 0.06 ms | 0.18 to 0.22 ms | Runtimes in S7-400 | 0.01 to 0.03 ms | 0.01 to 0.02 m | 0.01 to 0.04 ms | Target system | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC |
Standard function blocks | DEAD_T | DEAD_BAND | DIF |
|---|
Storage space requirements | Load memory | Work memory | Load memory | Work memory | Load memory | Work memory | | 532 bytes | 394 bytes | 232 bytes | 120 bytes | 410 bytes | 268 bytes | | 142 bytes | 22 bytes | 114 bytes | 16 bytes | 158 bytes | 30 bytes | Runtimes in S7-300 | 0.26 to 0.33 ms | 0.16 to 0.21 ms | 0.55 to 0.71 ms | Runtimes in S7-400 | 0.02 to 0.06 m | 0.01 to 0.03 ms | 0.03 to 0.09 ms | Target system | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC |
Standard function blocks | ERR_MON | INTEG | LAG1ST |
|---|
Storage space requirements | Load memory | Work memory | Load memory | Work memory | Load memory | Work memory | | 558 bytes | 360 bytes | 488 bytes | 314 bytes | 534 bytes | 368 bytes | | 206 bytes | 52 bytes | 168 bytes | 36 bytes | 156 bytes | 30 bytes | Runtimes in S7-300 | 0.27 to 0.35 ms | 0.40 to 0.51 ms | 0.52 to 0.67 ms | Runtimes in S7-400 | 0.01 to 0.05 ms | 0.02 to 0.07 ms | 0.03 to 0.09 ms | Target system | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC |
Standard function blocks | LAG2ND | LIMALARM | LIMITER |
|---|
Storage space requirements | Load memory | Work memory | Load memory | Work memory | Load memory | Work memory | | 690 bytes | 516 bytes | 390 bytes | 240 bytes | 262 bytes | 140 bytes | | 190 bytes | 46 bytes | 152 bytes | 28 bytes | 124 bytes | 20 bytes | Runtimes in S7-300 | 0.88 to 1.14 ms | 0.47 to 0.61 ms | 0.14 to 0.17 ms | Runtimes in S7-400 | 0.04 to 0.16 ms | 0.02 to 0.07 ms | 0.03 to 0.01 ms | Target system | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC |
Standard function blocks | LMNGEN_C | LMNGEN_S | NONLIN |
|---|
Storage space requirements | Load memory | Work memory | Load memory | Work memory | Load memory | Work memory | | 1576 bytes | 1280 bytes | 2578 bytes | 2152 bytes | 826 bytes | 672 bytes | | 276 bytes | 80 bytes | 360 bytes | 110 bytes | 138 bytes | 18 bytes | Runtimes in S7-300 | 0.32 to 0.41 ms | 1.16 to 1.47 ms | 0.32 to 0.41 ms | Runtimes in S7-400 | 0.02 to 0.06 ms | 0.06 to 0.18 ms | 0.02 to 0.07 ms | Target system | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC |
Standard function blocks | NORM | OVERRIDE | PARA_CTL |
|---|
Storage space requirements | Load memory | Work memory | Load memory | Work memory | Load memory | Work memory | | 234 bytes | 122 bytes | 362 bytes | 214 bytes | 406 bytes | 232 bytes | | 130 bytes | 24 bytes | 146 bytes | 28 bytes | 234 bytes | 82 bytes | Runtimes in S7-300 | 0.33 to 0.43 ms | 0.15 to 0.18 ms | 0.12 to 0.15 ms | Runtimes in S7-400 | 0.02 to 0.07 ms | 0.01 to 0.04 ms | 0.01 to 0.03 ms | Target system | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC |
Standard function blocks | PID | PULSEGEN | RMP_SOAK |
|---|
Storage space requirements | Load memory | Work memory | Load memory | Work memory | Load memory | Work memory | | 1560 bytes | 1242 bytes | 1110 bytes | 872 bytes | 1706 bytes | 1500 bytes | | 340 bytes | 98 bytes | 190 bytes | 34 bytes | 212 bytes | 62 bytes | Runtimes in S7-300 | 1.15 to 1.46 ms | 0.17 to 0.20 ms | 0.16 to 0.20 ms | Runtimes in S7-400 | 0.06 to 0.18 ms | 0.01 to 0.05 ms | 0.01 to 0.04 ms | Target system | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC |
Standard function blocks | ROC_LIM | SCALE | SP_GEN |
|---|
Storage space requirements | Load memory | Work memory | Load memory | Work memory | Load memory | Work memory | | 1242 bytes | 980 bytes | 136 bytes | 32 bytes | 658 bytes | 484 bytes | | 222 bytes | 50 bytes | 114 bytes | 16 bytes | 164 bytes | 40 bytes | Runtimes in S7-300 | 0.53 to 0.68 ms | 0.10 to 0.13 ms | 0.27 to 0.35 ms | Runtimes in S7-400 | 0.02 to 0.09 ms | 0.01 to 0.02 ms | 0.02 to 0.06 ms | Target system | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC |
Standard function blocks | SPLT_RAN | SWITCH | LP_SCHED |
|---|
Storage space requirements | Load memory | Work memory | Load memory | Work memory | Load memory | Work memory | | 304 bytes | 180 bytes | 238 bytes | 116 bytes | 1104 bytes | 972 bytes1) | | 138 bytes | 28 bytes | 118 bytes | 18 bytes | 234 bytes | 64 bytes1) | Runtimes in S7-300 | 0.09 to 0.11 ms | 0.07 to 0.09 ms | 0.28 to 0.34 ms | Runtimes in S7-400 | 0.01 to 0.02 ms | 0.01 to 0.03 ms | 0.03 to 0.08 ms | Target system | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC | SIMATIC S7-300 (CPU 313 and higher), S7-400, WinAC |
1) With 5 control loops Standard FBs in general | | Required libraries | Modular PID Control FBs | Licensing forms | Simple license and 1 runtime license; 1 runtime license | Software class | A | Current version | V 5.1 | Required software packages | STEP 7 V5.3 SP2 or higher | Main memory configuration in PG/PC | 16 MB | Disk space required in PG/PC | 1.85 MB |
|
|