10 ЛИСТОВ ФОРМАТА DIN A4: БЕЛЫЙ ЦВЕТ, 60 ЭТИКЕТОК ДЛЯ МОДУЛЕЙ ВВОДА-ВЫВОДА И 20 ЭТИКЕТОК ДЛЯ ИНТЕРФЕЙСНЫХ МОДУЛЕЙ; ПЕРФОРИРОВАННЫЙ ПЛАСТИК; МАРКИРОВКА НА ЛАЗЕРНОМ ПРИНТЕРЕ ИЛИ ПЛОТТЕРЕ, УПАКОВКА ИЗ 10 ЛИСТОВ
54.70 ?
SIPLUS master interface modules for IM 151 CPU
PROFIBUS DP master interface module for interface module IM 151-7 (R) CPU / IM 151-8 (F) PN/DP CPU
Integrated 12 Mbit/s PROFIBUS DP master interface in Cu version
Allows parallel operation of two PROFIBUS DP interfaces on one IM 151-7 CPU
Allows operation of one PROFIBUS DP interface with an IM 151-8 (F) PN/DP CPU
Increase in availability of systems and machines
Functionality in accordance with a DP master configured interface of an S7-314 CPU
Programming is performed with STEP 7 from version V5.2 with Service Pack 1.
Note:
SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme specific information was added.
SIPLUS master interface module for IM 151 CPU
Article No.
6AG1 138-4HA00-7AB0
BasedOn Article No.
6ES7 138-4HA00-0AB0
Ambient temperature range
-25 °C … +70 °C
Conformal coating
Coating of the printed circuit boards and the electronic components
Technical data
The technical data of the standard product applies except for the ambient conditions.
Ambient conditions
Relative humidity
100%, condensation/frost permitted. No commissioning in bedewed state.
Biologically active substances, compliance with EN 60721-3-3
Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!
Chemically active substances, compliance with EN 60721-3-3
Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must remain in place over the unused interfaces during operation!
Mechanically active substances, compliance with EN 60721-3-3
Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation!
Air pressure (depending on the highest positive temperature range specified)
1 080 ... 795 hPa (-1 000 … +2 000 m)
See ambient temperature range
795 ... 658 hPa (+2 000 ... +3 500 m)
derating 10 K 658 … 540 hPa (+3 500 … +5 000 m) derating 20 K