WirelessHART Pressure Transmitter SITRANS P280
|
|
Mode of operation
|
|
|
Measuring principle
|
piezo-resistive
|
|
Measured variable
|
Gauge and absolute pressure
|
|
Gauge pressure input
|
|
|
Measuring range
|
Overload limit/Bursting pressure
|
|
0 ... 2 bar g
|
5 bar g (72.5 psi g)
|
|
0 ... 10 bar g
|
50 bar g (363 psi g)
|
|
0 ... 50 bar g
|
250 bar g (1740 psi g)
|
|
0 ... 200 bar g
|
650 bar g (7250 psi g)
|
|
0 ... 400 bar g
|
650 bar g (7250 psi g)
|
|
Units
|
mbar, bar, mmH2O, inH2O, atm, Torr, gcm², kgcm², mPa, kPa, Pa, psi, mmHG, mmH2O, ftH2O, inHG, inH2O
|
|
Absolute pressure input
|
|
|
Measuring range
|
Overload limit/Bursting pressure
|
|
0 ... 2 bar a
|
5 bar a (72.5 psi a)
|
|
0 ... 10 bar a
|
50 bar a (363 psi a)
|
|
0 ... 50 bar a
|
250 bar a (1740 psi a)
|
|
0 ... 200 bar a
|
650 bar a (7250 psi a)
|
|
0 ... 400 bar a
|
650 bar a (7250 psi a)
|
|
Units
|
mbar, bar, mmH2O, inH2O, atm, Torr, gcm², kgcm², mPa, kPa, Pa, psi, mmHG, mmH2O, ftH2O, inHG, inH2O
|
|
Output
|
|
|
Output signal
|
2.4 GHz Wireless signal with TSMP (Time Synchronized Mesh Protocol)
|
|
Measuring accuracy
|
as per EN60770-1
|
|
Error in measurement (including hysteresis and repeatability, at 25 °C (77 °F))
|
max. ± 0.325 % of sensor's span
|
|
Long-term drift
|
max. ≤ 0.25 % of sensor's/yearly span
|
|
Ambient temperature effect
|
max. ≤ 0.025 %/K of sensor's span
|
|
Rated conditions
|
|
|
Ambient conditions
|
|
|
Ambient temperature
|
-40 ... +80 °C (-40 ... +176 °F) (in ambient temperatures below -20 °C (-4 °F) and above +70 °C (158 °F), readability of the display is limited.)
|
|
Storage temperature
|
-40 ... +85 °C (-40 ... +185 °F)
|
|
Relative humidity
|
< 95 %
|
|
Climatic class
|
4K4H in accordance with EN 60721-3-4 (stationary use at locations not protected against weather)
|
|
Degree of protection
|
IP65/NEMA 4
|
|
Design
|
|
|
Enclosure material
|
low-copper die-cast aluminum, GD-AISi12
|
|
Shock resistance
|
in accordance with DIN EN 60068-2-29/03.95
|
|
Resistance to vibration
|
in accordance with DIN EN 60068-2-6/12.07
20 ≤ f ≤ 2000 Hz
0.01 g²/Hz
|
|
Weight
|
|
|
|
1.5 kg (3.31 lb)
|
|
|
1.6 kg (3.53 lb)
|
|
Dimensions (W x H x D)
|
See Dimensional drawing
|
|
Process connection
|
- G½B male thread as per EN837-1
- ½-14 NPT
|
|
Sensor break
|
Is recognized
|
|
|
|
|
Display (with illumination)
|
|
|
|
104 x 80 pixels
|
|
|
adjustable
|
- Number of spaces after comma
|
adjustable
|
|
Setting options
|
- on site with 3 push buttons
- with SIMATIC PDM or HART Communicator
|
|
Auxiliary power
|
|
|
Battery
|
3.6 V DC
|
|
Communication
|
|
|
Radio
|
WirelessHART V7.1 conforming
|
|
Transmission frequency band
|
2.4 GHz (ISM-Band)
|
|
Transmission range under reference conditions
|
Up to 250 m (line of sight) in outside areas
Up to 50 m (greatly dependent on obstacles) in inside areas
|
|
Communication interfaces
|
- HART communication with HART modem
- WirelessHART
|
|
Certificates and approvals
|
|
|
Wireless communication approvals
|
R&TTE
FCC
|
|
Classification according to PED 97/23/EC
|
Gases: Fluid group 1
Liquids: Fluid group 1;
meets requirements as per Section 3, Subsection 3 (good engineering practice)
|