Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru

A5E00057317


Внимание! Указаны цены архивного каталога СА01. Для уточнения актуальной цены перейдите по ссылке заказного номера товара или перейдите в каталог СА01 2016

Заказной номерВесPGОписание продуктаЦена
A5E000573170.5822ADDITIONAL ELECTRONICS PROFIBUS PA EX I (FOR FIELD UNITS)1764.9

Field device

OXYMAT 6, field device

General information

Measuring ranges

4, internally and externally switchable; autoranging is also possible

Smallest possible span (relating to sample gas pressure 1 000 hPa absolute, 0.5 l/min sample gas flow and 25 °C ambient temperature), smallest possible span with heated version: 0.5% (< 65 °C); 0.5 … 1% (65 … 90 °C); 1 … 2% (90 … 130 °C))

0.5 vol.%, 2 vol.% or 5 vol.% O2

Largest possible measuring span

100 vol.% O2(for a pressure above 2 000 hPa: 25 vol.% O2)

Measuring ranges with suppressed zero point

Any zero point can be implemented within 0 … 100 vol.%, provided that a suitable reference gas is used (see Table 1 in "Function")

Operating position

Front wall, vertical

Conformity

CE mark in accordance with EN 50081-1, EN 50082-2

Design, enclosure

Degree of protection

IP65 in accordance with EN 60529, restricted breathing enclosure to EN 50021

Weight

Approx. 28 kg

Electrical characteristics

Power supply

100 … 120 V AC (nominal range of use 90 … 132 V), 48 … 63 Hz or 200 … 240 V AC (nominal range of use 180 … 264 V), 48 … 63 Hz

Power consumption

Approx. 35 VA, approx. 330 VA with heated version

EMC (ElectromagneticCompatibility)

In accordance with standard requirements of NAMUR NE21 (08/98), EN 61326, EN 50270 (with gas warning unit)

Electrical safety

In accordance with EN 61010-1

  • Heated units

Overvoltage category II

  • Unheated units

Overvoltage category III

Fuse values (unheated unit)

  • 100 ... 120 V

F3: 1 T/250; F4: 1 T/250

  • 200 ... 240 V

F3: 0.63 T/250; F4: 0.63 T/250

Fuse values (heated unit)

  • 100 ... 120 V

F1: 1 T/250; F2: 4 T/250

F3: 4 T/250; F4: 4 T/250

  • 200 ... 240 V

F1: 0.63 T/250; F2: 2.5 T/250

F3: 2.5 T/250; F4: 2.5 T/250

Gas inlet conditions

Permissible sample gas pressure

  • With pipes

500 … 3 000 hPa absolute

  • With pipes, Ex version

  • Leakage compensation

500 … 1 160 hPa absolute

  • Continuous purging

500 … 3 000 hPa absolute

Reference gas pressure (high-pressure version)

2 000 ... 4 000 hPa above sample gas pressure, but max. 5 000 hPa

Reference gas pressure (low-pressure version)

Min. 100 hPa above sample gas pressure

Purging gas pressure

  • Permanent

< 165 hPa above ambient pressure

  • For short periods

Max. 250 hPa above ambient pressure

Sample gas flow

18 … 60 l/h (0.3 … 1 l/min)

Sample gas temperature

  • Min. 0 to max. 50 °C, but above the dew point (unheated)
  • 15 °C above temperature analyzer unit (heated)

Sample gas humidity

< 90% relative humidity

Dynamic response

Warm-up period

At room temperature < 30 min (the technical specification will be met after 2 hours)

Delayed display (t90-time)

< 1.5 s

Damping (electrical time constant)

0 … 100 s, parameterizable

Dead time (purging time of the gas path in the unit at 1 l/min)

Approx. 0.5 s

Time for device-internal signal processing

< 1 s

Pressure correction range

Pressure sensor

  • Internal

500 … 2 000 hPa absolute

  • External

500 … 3 000 hPa absolute

Measuring response(relating to sample gas pressure 1 013 hPa absolute, 0.5 l/min sample gas flow and 25 °C ambient temperature)

Output signal fluctuation

< ± 0.75% of the smallest possible measuring range according to rating plate, with electronic damping constant of 1 s (corresponds to ± 0.25% at 2  )

Zero point drift

< ± 0.5%/month of the smallest possible span according to rating plate

Measured-value drift

< ±0.5%/month of the current measuring range

Repeatability

< 1% of the current measuring range

Detection limit

1% of the current measuring range

Linearity error

< 0.1% of the current measuring range

Influencing variables(relating to sample gas pressure 1 013 hPa absolute, 0.5 l/min sample gas flow and 25 °C ambient temperature)

Ambient temperature

< 0.5%/10 K relating to the smallest possible measuring range according to rating plate, with measuring span 0.5%: 1%/10 K

Sample gas pressure (with air (100 hPa) as reference gas, correction of the atmospheric pressure fluctuations is only possible if the sample gas can vent to ambient air)

  • When pressure compensation is switched off: < 2% of the current measuring range/1% pressure change
  • When pressure compensation is switched on: < 0.2% of the current measuring range/1% pressure change

Carrier gases

Deviation from zero point corresponding to paramagnetic or diamagnetic deviation of carrier gas

Sample gas flow at zero point

< 1% of the current measuring range according to rating plate with a change in flow of 0.1 l/min within the permissible flow range; heated version up to double error

Power supply

< 0.1% of the current measuring range with rated voltage ± 10%

Electrical inputs and outputs

Analog output

0/2/4 … 20 mA, isolated; max. load 750 

Relay outputs

6, with changeover contacts, freely parameterizable, e.g. for measuring range identification; load: 24 V AC/DC/1 A, isolated

Analog inputs

2, dimensioned for 0/2/4 ... 20 mA for external pressure sensor and residual gas influence correction (correction of cross-interference)

Binary inputs

6, designed for 24 V, isolated, freely parameterizable, e.g. for measuring range switchover

Serial interface

RS 485

Options

AUTOCAL function with 8 additional binary inputs and relay outputs each, also with PROFIBUS PA or PROFIBUS DP

Climatic conditions

Permissible ambient temperature

-30 … +70 °C during storage and transportation, 5 … 45 °C during operation

Permissible humidity

< 90% RH (relative humidity) as annual average (maximum accuracy achieved after 2 hours), during storage and transportation (dew point must not be undershot)
























































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Контрольно-измерительные приборы Анализаторы процесса Непрерывные анализаторы газов Непрерывные анализаторы газов, эктрактивные Введение ULTRAMAT 23 ULTRAMAT 6 ULTRAMAT/OXYMAT 6 OXYMAT 6 General information 19" rack unit Field device Documentation Suggestions for spare parts OXYMAT 61 OXYMAT 64 CALOMAT 6 CALOMAT 62 FIDAMAT 6 Непрерывный газовый анализ, in-situ Промышленные газовые хроматографы Analytical Application Sets General information Технологии взвешивания Датчики зрения Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366
Яндекс.Метрика