6AU1820-3DA20-0AB0
Внимание! Указаны цены архивного каталога СА01. Для уточнения актуальной цены перейдите по ссылке заказного номера товара или перейдите в каталог СА01 2016
Заказной номер | Вес | PG | Описание продукта | Цена |
6AU1820-3DA20-0AB0 | 0.01 | 731 | SIMOTION ТЕХНОЛОГИЧЕСКАЯ ФУНКЦИЯ OA MICRO INNOVATION INTERFACE (OA MIIF) СПЕЦ. ПО ПОЛЬЗОВАТЕЛЯ ДЛЯ BOSCH SIGPACK ПРОСТАЯ ЛЕЦЕНЗИЯ ДЛЯ ОДНОГО КОНЕЧНОГО УСТРОЙСТВА | 374.34 |
Runtime licenses for SIMOTION C, D
Licenses for runtime software for SIMOTION C, D can be ordered individually or pre-installed (by order code/Z option) on memory card.
In both cases, the license certificate is enclosed.
Runtime licenses for SIMOTION P
Licenses for runtime software for SIMOTION P can be ordered individually or by means of order code (Z option).
When ordered by means of order code (Z option), the runtime licenses are not pre-installed in this case, the license certificate is enclosed.
Exception:
When the MultiAxes Package license for SIMOTION P350-3 is ordered by way of order code M35, the license is pre-installed on the system.
Ordering individual licenses
The order numbers can be found in column "Single-user license" in the selection and ordering data table.
If several licenses of the same type are needed, e.g. 3 x POS license, the order number must be repeated for each license.
Example:
A 1 GB CompactFlash card for SIMOTION D4x5-2 has been purchased, but without pre-installed runtime licenses. During the configuring process with SIMOTION SCOUT, a message is displayed to indicate that the following runtime licenses are needed: 1 x POS axis license, 1 x TControl license.
The table of selection and ordering data provides:
- POS axis license: 6AU1820-1AA20-0AB0
- TControl license: 6AU1820-2AA20-0AB0
Ordering pre-installed licenses
To order pre-installed licenses, the type and number of the required licenses must be specified in the order using order codes (Z options). These order codes are added to the order number for the memory card.
Step 1: Specifiy the order no. of the SIMOTION memory card first:
- Memory card for SIMOTION C:
Micro Memory Card 64 MB: 6AU1720-1KA00-0AA0 - Memory card for SIMOTION D410, D4x5:
CompactFlash Card 1 GB: 6AU1400-2PA01-0AA0 - Memory card for SIMOTION D4x5-2:
CompactFlash Card 1 GB: 6AU1400-2PA21-0AA0
Step 2: The following order codes specify the type and number of the required runtime licenses:
The order codes are indicated by means of “-Z“ and can be found in column “Order codes for pre-installed licenses” in the selection and ordering data table.
Example 1:
Micro Memory Card 64 MB for SIMOTION C240 with
- MultiAxes Package license
for SIMOTION C2xx:
Order No.: 6AU1720-1KA00-0AA0-Z M24
Example 2:
CompactFlash Card 1 GB for SIMOTION D4x5-2 with
- 3 POS licenses,
- 2 CAM licenses,
- 1 TControl license and
- 1 Safety Integrated Extended Functions license:
Order No.: 6AU1400-2PA21-0AA0-Z P03 C02 T01 F01
Configurator for runtime licenses
An electronic ordering configurator is available in the Industry Mall for ordering SIMOTION hardware with corresponding runtime licenses.
Homepage:http://www.siemens.com/industrymall
This will guide you step by step through the process of selecting and ordering SIMOTION hardware with pre-installed runtime licenses.
Selection and ordering data
License type |
Single-user license Order No. |
Order codes for pre-installed licenses on SIMOTION memory cards |
Licensed functions |
License |
Notes |
---|---|---|---|---|---|
Axis licenses |
|||||
|
6AU1820-1AA20-0AB0 |
Pxx – POS license and number (e.g. P02 = 2 POS licenses) |
Positioning |
Per axis |
Not required for D410 No path interpolation for D410 |
|
6AU1820-1AB20-0AB0 |
Gxx – GEAR license and number (e.g. G03 = 3 GEAR licenses) |
Positioning, synchronous operation, path interpolation |
||
|
6AU1820-1AC20-0AB0 |
Cxx – CAM license and number (e.g. C01 = 1 CAM license) |
Positioning, synchronous operation, path interpolation, cam (all functions of the Motion Control technology package) |
||
MultiAxes Packages |
|||||
|
6AU1820-0AA20-0AB0 |
M00 – MultiAxes Package license (platform independent) |
Positioning, synchronous operation, path interpolation, cam (all functions of the Motion Control technology package) |
Unlimited axes on one controller |
Not required for D410 |
|
6AU1820-0AA24-0AB0 |
M24 – MultiAxes Package license for C2xx |
|||
|
6AU1820-0AA32-0AB0 |
M32 – MultiAxes Package license for P320-3 |
|||
|
6AU1820-0AA35-0AB0 |
M35 – MultiAxes Package license for P350-3 |
|||
|
6AU1820-0AA42-0AB0 |
M42 – MultiAxes Package license for D425 |
|||
|
6AU1820-0AA43-0AB0 |
M43 – MultiAxes Package license for D435 |
|||
|
6AU1820-0AA44-0AB0 |
M44 – MultiAxes Package license for D445-x/D455-2 |
|||
Licenses for other technology packages / technology functions |
|||||
|
6AU1820-2AA20-0AB0 |
Txx – TControl license and number (e.g. T03 = 3 TControl licenses) |
Temperature control |
8 temperature channels per license |
|
|
6AU1820-3BA20-0AB0 |
B01 – DPM license |
Direct Product Motion (product infeed) |
Per controller |
On one C2xx, P3xx, D435 or D445-x/D455-2 |
|
6AU1820-3DA20-0AB0 |
B02 – MIIF license |
Multipurpose Information Interface |
Per controller |
On one C2xx, P3xx or D4x5/D4x5-2 |
|
6AU1820-2AF20-0AB0 |
Fxx – Safety license and number |
SINAMICS Safety Integrated Extended Functions for SIMOTION D |
Per safety axis with Safety Integrated Extended Functions |
For integrated SINAMICS drives with SIMOTION D and Controller Extension CX32/CX32-2 |
Licenses for SIMOTION IT communication functions |
|||||
|
6AU1820-8BA20-0AB0 |
D00 – IT DIAG license |
Integrated web server |
Per controller |
On platforms with Ethernet and/or PROFINET interface |
|
6AU1820-8BB20-0AB0 |
X00– IT OPC XML-DA license |
Communikation via OPC XML-DA |
Per controller |
|
|
6AU1820-8BD20-0AB0 |
J00– SIMOTION IT Virtual Machine license |
With SIMOTION Kernel < V4.2 as combined license for SIMOTION IT DIAG, OPC XML-DA and Virtual Machine. |
Per controller |
|
License for SIMATIC NET OPC server on SIMOTION P |
|||||
|
6AU1380-0AA20-0YB0 |
K00 – OPC server license, on SIMOTION P, XP variant |
1)Requires a license for SIMOTION Kernel < V4.2