3SX5601-2GA03


Внимание! Указаны цены архивного каталога СА01. Для уточнения актуальной цены перейдите по ссылке заказного номера товара или перейдите в каталог СА01 2016

Заказной номерВесPGОписание продуктаЦена
3SX5601-2GA030.1641KCABLE. 8-PIN. FREE CABLE END 3M LONG. FOR RFID SAFETY SWITCH 3SE63. ON STRAIGHT SOCKET M12. FOR 2A AND 30V40.02

SIRIUS 3SE63 Contact-free Safety Switches, RFID

RFID 3SE63 contactless safety switches meet the highest safety requirements, SIL3 or Cat. 4, for monitoring the positions of movable protective devices.

An RFID safety switch consists of a coded RFID switch with an 8-pole M12 connector plug and an identical RFID actuator.

The switch is available in several versions:

  • Family coded with M12 plug or with additional 18 N magnetic catch as an option
  • Individually coded, programmable once, with M12 plug or with additional 18 N magnetic catch as an option
  • Individually coded, programmable more than once (an unlimited number of times), with M12 plug or variant with additional 18 N magnetic catch

The actuator is therefore available in two versions:

  • Standard
  • With 18 N magnetic catch

The magnetic catch keeps doors and flaps closed with permanent magnets.

Optional accessories

Covers for sealing mounting holes, also suitable for tamper-proofing screw fixings

Spacers (approx. 3 mm high) to facilitate cleaning under the installation surface when using pressure washers, for example

Mounting and maintenance

Reduction in the number of versions, because

  • switches can be mounted on right or left sides
  • the actuator can be mounted on all sides

Quick and easy mounting by thanks to universal mounting holes

  • Standard gauge/holes for 3SE6 magnetically operated switch
  • Fine adjustment thanks to slotted holes

Little adjustment or maintenance required

  • Threshold indication by LED switch for quick and easy adjustment during installation and maintenance
  • Molded switch allows it to be used as an end stop for small and medium-sized doors

Note:

Keep metal parts and cuttings away from the vicinity of the switch

Minimum distance between two switches 100 mm

Coding

Family coded

These safety switches are delivered ready to use, i. e. no programming is necessary.

Individually coded, programmable once

The assignment of safety switch and actuator thus created is irreversible.

The actuator is programmed simply by routine during startup, thus permanently preventing any form of tampering by means of a replacement actuator.

Individually coded, programmable several times

The procedure for programming a new actuator can be repeated an unlimited number of times. When a new actuator is programmed the previous code becomes invalid. A protected coding process allows new actuators to be programmed for service purposes.

After this, a ten-minute lockout provides enhanced tamper protection. The green LED flashes until the lockout time has ended and the new actuator has been detected. If the operational voltage is interrupted during this time, the ten-minute guard time is restarted.

Programming procedure for individual coding

1. Apply operational voltage to safety sensor

2. Move actuator into detecting range: red LED lights up, yellow LED flashes (1 Hz)

3. After 10 s it changes to a shorter flashing frequency (3 Hz). In this state switch off operational voltage.

4. After the next time the operational voltage is switched on, the actuator is detected again to activate the programmed actuator code. The activated code is thus stored permanently.

Diagnostics

The RFID safety switch indicates its operating state including faults by means of the LED indicator in the switch and the short circuit-resistant diagnostic output. The signals can then be used for central displays or non-safety-related control tasks.

There are two diagnostics functions:

  • Crossover monitoring
  • Open-circuit monitoring
  • External voltage monitoring
  • Ambient temperature too high
  • Wrong or defective actuator
  • Switching interval threshold identification with LED indication

The signal combination "diagnostics output switched off" and "safety outputs still switched on" can be used to move the machine into a controlled stop position.

Any crossover or a fault that is not currently compromising the safe operation of a safety switch results in the disconnection of the safety channels after a 30 minute delay. However, the diagnostics output switches off instantaneously.

Mode of operation of the diagnostics LEDs

The safety switch indicates not only its operating state, but also faults by means of LEDs in three colors at the ends of the RFID switch.

  • The green LED indicates readiness for operation when the control supply voltage is connected.
  • The yellow LED indicates that there is an actuator in detecting range. If the actuator is in the switching interval threshold, this is indicated by flashing. This flashing can be used to identify a change in the distance between sensor and actuator at an early stage (e. g. as a result of the sagging of a protective door). The installation should be tested before the distance increases further, the safety outputs switch off and the machine stops.
  • The red LED indicates the individual causes of the fault by means of defined flashing frequencies.






















































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Промышленные аппараты управления SIRIUS Системы Коммутационные аппараты SIRIUS Аппаратура защиты Фидеры и пускатели двигателей Функциональные, коммутирующие реле и преобразователи Sicherheitstechnik Позиционные выключатели и выключатели для систем безопасности Позиционные выключатели SIRIUS Магнитные выключатели SIRIUS 3SE6 SIRIUS 3SE63 Contact-free Safety Switches, RFID Устройства управления и индикации Трансформаторы и блоки питания Другие продукты и решения Планирование и конфигурирование для SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо