Заказной номерВесPGОписание продуктаЦена
1LE1011-1BJ2.-....273Z1LOW-VOLTAGE MOTOR. IEC SQUIRREL-CAGE.SELF-COOLED..IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING. 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS112M* 3.7/4.4KW (50HZ)1496

Цена на сайте указана розничная в ЕВРО без учета НДС.
Для уточнения цены и размера предоставляемой скидки - звоните или присылайте заявки

Заказной номерPGОписание продуктаЦена
1LE1011-1AJ4.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS100L* 2.0/2.4KW (50HZ) 1006.50
1LE1011-1AJ5.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS100L* 2.6/3.1KW (50HZ) 1199.00
1LE1011-1AL4.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS100L* 0.55/1.1KW (50HZ) 845.90
1LE1011-1AL5.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS100L* 0.9/1.5KW (50HZ) 976.80
1LE1011-1AP4.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS100L* 0.65/2.5KW (50HZ) 1006.50
1LE1011-1AP5.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS100L* 0.8/3.1KW (50HZ) 1199.00
1LE1011-1AR4.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS100L* 0.5/2.0KW (50HZ) 845.90
1LE1011-1AR5.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS100L* 0.65/2.5KW (50HZ) 976.80
1LE1011-1BJ2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS112M* 3.7/4.4KW (50HZ) 1496.00
1LE1011-1BL2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS112M* 1.1/1.9KW (50HZ) 1133.00
1LE1011-1BP2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS112M* 1.1./4.4KW (50HZ) 1496.00
1LE1011-1BR2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS112M* 0.9/3.6KW (50HZ) 1133.00
1LE1011-1CJ0.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS132S* 4.7/5.9KW (50HZ) 1914.00
1LE1011-1CJ2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS132M* 6.5/8.0KW (50HZ) 2508.00
1LE1011-1CL0.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS132S* 1.6/3.2KW (50HZ) 1584.00
1LE1011-1CL2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS132M* 2.2/4.4KW (50HZ) 2046.00
1LE1011-1CP0.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS132S* 1.45/5.9KW (50HZ) 1914.00
1LE1011-1CP2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS132M* 2.0/8.0KW (50HZ) 2508.00
1LE1011-1CR0.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS132S* 1.1/4.7KW (50HZ) 1584.00
1LE1011-1CR2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS132M* 1.4/6.4KW (50HZ) 2046.00
1LE1011-1DJ2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS160M* 9.3/11.5KW (50HZ) 3322.00
1LE1011-1DL2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS160M* 3.5/7.0KW (50HZ) 2816.00
1LE1011-1DL4.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS160L* 5.6/11.0KW (50HZ) 4180.00
1LE1011-1DP2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 4/2POLE*FS160M* 2.9/11.5KW (50HZ) 3322.00
1LE1011-1DR2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS160M* 2.2/9.5KW (50HZ) 2816.00
1LE1011-1DR4.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, 1 WINDING IN DAHLANDER CIRCUIT 8/4POLE*FS160L* 3.3/14.0KW (50HZ) 4180.00
1LE1012-1AQ4.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, WITH 2 WINDINGS 6/4POLE*FS100L* 0.6/1.7KW (50HZ) 1075.80
1LE1012-1AQ5.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, WITH 2 WINDINGS 6/4POLE*FS100L* 0.75/2.1KW (50HZ) 1199.00
1LE1012-1BQ2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, WITH 2 WINDINGS 6/4POLE*FS112M* 0.9/3.0KW (50HZ) 1397.00
1LE1012-1CQ0.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, WITH 2 WINDINGS 6/4POLE*FS132S* 1.2/3.9KW (50HZ) 1727.00
1LE1012-1CQ2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, WITH 2 WINDINGS 6/4POLE*FS132M* 1.7/5.4KW (50HZ) 2123.00
1LE1012-1DQ2.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, WITH 2 WINDINGS 6/4POLE*FS160M* 2.5/7.2KW (50HZ) 3102.00
1LE1012-1DQ4.-....3Z1LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-COOLED.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) ALUMINIUM HOUSING FOR DRIVING VANS 2-POLE CHANGING, WITH 2 WINDINGS 6/4POLE*FS160L* 3.7/12.0KW (50HZ) 4510.00






















































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Преобразователи Двигатели переменного тока Низковольтные электродвигатели (стандартные промышленные двигатели) Введение Стандартные электродвигатели IEC Ассинхронные электродвигатели с короткозамкнутым ротором 1LE1/1PC1 Введение Основная линейка двигателей с укороченным сроком поставки - 1LE1 Самовентилируемые многоскоростные двигатели серии 1LE1 Самовентилируемые энергосберегающие двигатели улучшенной эффективности - 1LE1 Самовентилируемые энергосберегающие двигатели высокоэффективные - 1LE1 Самовентилируемые двигатели увеличенной мощности и улучшенной эффективности - 1LE1 Самовентилируемые двигатели увеличенной мощности и повышенной эффективности - 1LE1 Принудительно-охлаждаемые двигатели без внешнего вентилятора и крышки вентилятора, улучшенной эффективности - 1LE1 Принудительно-охлаждаемые двигатели без внешнего вентилятора и крышки вентилятора, высокоэффективные - 1LE1 Самоохлаждаемые двигатели без внешнего вентилятора и крышки вентилятора, улучшенной эффективности - 1PC1 Самоохлаждаемые двигатели без внешнего вентилятора и крышки вентилятора, высокоэффективные - 1PC1 Специальное исполнение Аксессуары Габаритные размеры Стандартные двигатели до типоразмера 315 L Двигатели для работы от преобразователя частоты Двигатели для насосов Двигатели для вентиляторов Двигатели для компрессоров Нестандартные электродвигатели, размера 315 и выше Ex электродвигатели Двигатели для определенных секторов промышленности Приложения Серводвигатели и двигатели главного движения Прямые двигатели Высоковольтные двигатели Двигатели постоянного тока Системы измерения Мотор-редукторы Инструментальное программное обеспечение Дополнительные компоненты Технологии приводов для экстремальных условий Техника автоматизации Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо